INTRODUCING THE ZON E LIN E UltimateV10 ® ARCHITECTS & ENGINEERS DATA MANUAL 10 innovative features that create the ultimate owner, guest and installer experience.
INTRODUCING THE ZON E LIN E UltimateV10 ® Designed, engineered and assembled in the U.S., Zoneline UltimateV10 units provide unrivaled reliability, consistent performance and constant guest comfort.
1 5 Q U I C K- I N S TA L L PLENUM 6 U LT R A - Q U I E T 7 REVERSE C YC L E DEFROST 8 P R E M I U M G UA R D S E ACOA S T P R OT E C T I O N 9 O N B OA R D D I AG N O S T I C S I N S TA - P L AT F O R M ™ 10 S m a r t HQ ™ W I F I 2 S E L F - CO N TA I N E D D R A I N AG E S YS T E M 3 FA S T- CO N N E C T P L U M B I N G 4 S E L F - A L I G N I N G , L O C K- I N - P L AC E S YS T E M C A PA B I L I T Y geappliances.
F E ATU R E S & B E N E F IT S EXCELLENT EFFICIENCY AND DEHUMIDIFICATION GE Appliances recognizes the importance of energy efficiency and dehumidification in an air conditioning system and uses EER (Energy Efficiency Rating) as the required means of reporting the relative cooling efficiency of the unit. The measurement of the efficiency of the heat pump output, when compared to electric resistance heat, is called the Coefficient of Performance (COP).
F E ATU R E S & B E N E F IT S TWO-SPEED INDOOR FAN MOTOR FOR SELECTABLE HIGH AND LOW SPEEDS Since the Zoneline Vertical chassis discharge air may be routed through duct work for air distribution into one or more rooms, the units are equipped with a two-speed fan that provides greater air movement to compensate for the additional duct length. GE Appliances recommends an HVAC engineer be consulted to determine the best fan speed for the application.
F E ATU R E S & B E N E F IT S HEAT PUMP OPERATION HEAT PUMP DEFROST Heat pumps save money compared to electric resistance heat, but if the unit cannot provide room occupant comfort, the savings may be of questionable benefit. GE Appliances has years of experience with designing Zoneline® heat pumps to solve the problem of guest complaints. The heat pump unit uses a two-stage heat/one-stage cooling thermostat.
CO M P O N E NT S & I N STALL ATI O N Each Zoneline single packaged vertical unit requires a drain platform, wall plenum, exterior grille, unit, remote thermostat, power connection kit, return air grille/access panel, filter, ductwork and supply registers. The drain platform legs, ductwork and supply registers are field supplied. Each of the other components is ordered separately.
E S S E NTIAL PAR T S AN D ACCE S SO R I E S These essential accessories and components are integral to installation and required for satisfactory performance over a wide range of operating conditions.
CO M P O N E NT S & I N STALL ATI O N STANDARD SIZE AIR FILTER A number of filters, providing varying degrees of filtering efficiency, are available on the market today. GE Appliances has designed the Zoneline® Vertical chassis to accommodate a number of filter placement options. The filter provided with the unit is a standard size 18" W x 20" H x 1" D filter. The unit must not be operated without a filter in place, even during construction.
CO M P O N E NT S & I N STALL ATI O N RETURN AIR GRILLE, ACCESS PANEL OR LOUVERED CLOSET DOOR The return air from the room to the unit may enter the closet through one of four ways. A louvered door may be installed on the closet to allow return air to enter. When a louvered door is used, the filter would be installed in the filter bracket on the front panel of the unit. A wall-mounted access panel may be used instead of a louvered door.
CO M P O N E NT S & I N STALL ATI O N REMOTE THERMOSTAT Zoneline® Vertical units are controlled by a wall-mounted thermostat. GE Appliances offers a complete line of thermostats to interface with the units, or most 24-VAC thermostats may be used. Low-voltage wiring connections are made to the 8-pin harness included with each unit. This harness allows for a single-point thermostat connection to simplify chassis removal and reinstallation. See diagram below for terminal designations.
T Y P I C AL UTI LIT Y CLOS E T AN D D I M E N S I O N S (FOR REFERENCE ONLY) FRONT INSTALL SIDE INSTALL Top View Top View Architectural Louver Architectural Louver 10” Duct 13½” 27 ¾” minimum 7.16” 3” minimum clearance 10” Duct 13½” 3” minimum clearance 3” minimum clearance 3” minimum clearance Door/access panel 7.
AUXI LIARY CO NTRO L S SETTING THE AUXILIARY CONTROL Auxiliary Controls-Aux Set Button The electronic control for the unit comes preset from the factory to control the unit how “most” customers would prefer the unit to operate. The presets (called modes or functions) can be modified to accommodate for differences in installation parameters or personal preferences on how the unit should operate and perform.
AUXI LIARY CO NTRO L S SETTING THE AUXILIARY CONTROL Mode 3 Freeze Sentinel/Heat Sentinel With power to the unit and Freeze Sentinel activated, the unit automatically provides heat without user interface. This prevents potential plumbing damage by turning the heater and indoor fan ON at 41o F and then OFF once the room temperature reaches 46o F. When Heat Sentinel is activated, the unit automatically provides cooling without user interface.
ACCE S SO R I E S 26-1/2″ ARCHITECTURAL LOUVER RAVAL3 23-3/4″ Cutout Dimensions: 24" W x 32" H RAVDPLAT Insta-Platform™ WALL PLENUM RAVWPT15 Telescopes from 8" to 15" 32-5/8″ 23-31/32″ 31-3/4″ 3-5/8″ 24-35/64″ 8″- 15″ 1-1/4″ RETURN AIR GRILLE RAVRG2 Filter size: 20" x 20" Field supplied 29-3/8″ ACCESS PANEL WITH RETURN AIR GRILLE RAVRG4 Filter size: 20" x 24" x 1 or 2" Field supplied 22-1/2" OR 57-3/8″ Cutout Dimensions: 28-1/8" W x 55-7/8" H 22-1/2" Cutout Dimensions: 20-3/8" W x 20-3/8"
COMPLETE ACCESSORY LIST KIT NUMBER DESCRIPTION RAK149F2 Digital Two-Fan-Speed Thermostat RAK149P2 Digital Programmable Thermostat RAK180W1 Energy Management Occupancy-Sensing Wired/Wireless Thermostat RAVAL3 Exterior Grille RAVRG2 Return Air Grille for Flush Door RAVRG4 Access Panel with Return Air RAVWPT15 Wall Plenum for walls 8" to 15" thick RAVTRANS2 Transition plenum to adapt existing AZ75/85 wall plenums to AZ95 series RAVTRANS3 Transition plenum to adapt existing 8"-deep (RAVWPT8)
E S S E NTIAL PAR T S AN D ACCE S SO R I E S The UltimateV10™ Vertical Air Conditioners require a set of essential accessories for proper operation.
E S S E NTIAL PAR T S AN D ACCE S SO R I E S PLENUM ADAPTERS RAVTRANS2 PLENUM ADAPTER to transition from existing AZ75/ AZ85 wall plenum to AZ95 unit RAVTRANS3 PLENUM ADAPTER RAVTRANS4 PLENUM ADAPTER to transition from existing AZ90/ AZ91 shallow plenum (RAVWPT8) to AZ95 unit to transition from existing AZ90/ AZ91 deep plenum (RAVWPT14) to AZ95 unit TELESCOPING WALL PLENUM AND INSTA-PLATFORM™ RAVWPT15 TELESCOPING PLENUM for wall depth 8"-15" Wall cutout: 24" x 32" RAVDPLAT INSTA-PLATFORM 24" W x 24-
R E M OTE TH E R M OSTAT S All Zoneline® Vertical units are compatible with GE Appliances’ wall-mounted remote thermostats.
geappliances.
ZO N E LI N E ® U LTI MATE V 1 0™ VE R TI C AL AI R CO N D ITI O N E R FEATURES • Excellent efficiency and dehumidification • Indoor frost control • Automatic compressor random restart • Permanently lubricated fan motors • Standard size air filter (18" x 20" x 1") included DESIGNED & ASSEMBLED IN • Compressor restart delay • Central desk control capability • Electronic control diagnostics/ Service Models • HI and LOW fan speeds controlled by remote thermostat • Warranty (including both parts and labor)
SPECIFICATIONS 230-208 VOLTAGE GE AZ95 SERIES - 230/208V* HEAT PUMP WITH BACKUP ELECTRIC HEAT AZ95H09DAC AZ95H12DAC Voltage FEATURES Cooling BTUH EER (min.) Cooling power (W) Cooling current (A) Sensible Heat Ratio (SHR) Dehumidification (pints per hour) Refrigerant Indoor CFM (hi/lo) (0.1 ESP) HEAT PUMP Heating BTU COP***(min.) Heating power (W) Heating current (A) CASE DIMENSIONS Width (in.) Depth (in.) Height (in.) Net weight (lbs.) Approx. ship. weight (lbs.) Clearances for front install (min.
S P ECI F I C ATI O N S The following are suggested specifications for the AZ95 Series single packaged vertical units: The contractor shall furnish single packaged vertical units of the sizes and capacities shown on the schedule or in the specifications. The units shall be located as shown on the drawings and each shall consist of a chassis, appropriately sized wall plenum, outdoor grille, remote wall thermostat, drain platform, and closet access panel or door.
G E AP P LIAN CE S VE R TI C AL ZO N E LI N E H E AT P U M P S AD D ITI O NAL S P ECI F I C ATI O N S Heat pump unit shall automatically switch from heat pump operation to electric resistance heat when it is unable to provide sufficient heat to maintain room temperature or when the outdoor temperature is 25o F or less.
ZO N E LI N E ® S I N G LE PACK AG E D VE R TI C AL U N IT N O M E N CL ATU R E The Vertical Zoneline chassis is identified by a model number defining the type of unit, cooling capacity, electrical information and optional features included on the unit. When specifying or ordering the Zoneline chassis, use of this nomenclature will ensure receiving the correct unit.
ZO N E LI N E WAR R ANT Y Proof of original purchase date is needed to obtain service under warranty. For service in the U.S., call 1-844-GE4-PTAC (1-844-434-7822). In Canada, contact your local distributor. WHAT IS NOT COVERED WHAT IS COVERED If you have an installation problem, or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.
GE is a trademark of the General Electric Company. Manufactured under trademark license. GE Appliances has a policy of continuous improvement of its products and reserves the right to change materials and specifications without notice. Appliance Park Louisville, KY 40225 geappliances.com Pub.