TYPICAL UTILITY CLOSET AND DIMENSIONS (FOR REFERENCE ONLY)
AVAILABLE ACCESSORIES
• Insta-Platform™—RAVDPLAT
• Architectural Louver—RAVAL3
• Wall Plenum—RAVWPT15—telescopes from 8" to 15"
• Access Panel with Return Air Grille—RAVRG4
• Return Air Grille—RAVRG2
• Wall Thermostat
*All variations beginning with this model number
FRONT INSTALL
Top View
Architectural Louver
3”
minimum
clearance
Thermostat
Connection
Unit
Front
3” minimum
clearance
3” minimum
Electrical
Connection
10”
Duct
27 ¾”
minimum
minimum
Door/access panel return air grille
Note: It is recommended to leave additional
space around the unit to ease installation
and access for service.
Top View
SIDE INSTALL
Thermostat
Connection
29 ⅝”
minimum
Electrical
Connection
3” minimum
clearance
Architectural Louver
10”
Duct
3”
minimum
clearance
Unit
Front
5” minimum
clearance
Door/access
panel
29 ¾”
minimum
Flexible or
rigid duct
30”
Side View
Exterior/Outside
Field supplied
flashing
Outside wall
Inside wall
Air
discharge
outlet
Rigid
ductwork
Filter bracket
Secure
Drain Platform
NOITALLATSNI TNORF •
– 3" minimum clearance from
front of case and 3” minimum
from two sides.
NOITALLATSNI EDIS •
– 5” minimum clearance from
front of case, 3” minimum from
access side and 3” minimum
from non access side.
Drain fittings
3
⁄4”
Unit
Option 2
Access panel with
return air grille
RAVRG4*
Option 1
Return air grille
RAVRG2*
(used with field
supplied closet door)
24
1
/8”
Wall
plenum
* Kits beginning with
29 ⅝”
13½”
7.16”
13½”
7.16”
Preliminary specifications. Subject to change.