Architect and Engineering Manual

18
ESSENTIAL PARTS AND ACCESSORIES
The UltimateV10
Vertical Air Conditioners require a set of essential accessories for proper operation.
Once you have selected the size of unit needed, next you’ll need to consider the following:
POWER CONNECTIONS - Must be directly connected
POWER CONNECTION REQUIREMENTS (RESISTANCE HEAT)
POWER CONNECTION REQUIREMENTS (RESISTANCE HEAT)
RAK315D/320D/330D
RAK320D SHOWN
230-208-Volt Universal
Direct Connect
Power Supply Kit
RAK515D/520D/530D
RAK520D SHOWN
265-Volt Universal
Direct Connect
Power Supply Kit
230 -208 VOLT 9,000/12,000 BTUh 18,000 BTUh*
POWER
CONNECTION KIT
RAK315D RAK320D RAK330D RAK320D RAK330D
Heater BTUh 8360/6838 11770/9629 17060/13952 11770/9629 17060/13952
Total Watt s 2568/2122 3568/2940 5118/4207 3568/2940 5118/4207
Heater Watts 2450/2004 3450/2822 5000/4089 3450/2822 5000/4089
Total Heating Amps 10.7/9.6 15/13.6 21.7/19.7 15/13.6 21.7/19.7
MCA
15
20 30
20 30
Recommend
Protective Device
(MOCP)
15 amp
time-delay
fuse or breaker
20 amp
time-delay
fuse or breaker
30 amp
time-delay
fuse or breaker
20 amp
time-delay
fuse or breaker
30 amp
time-delay
fuse or breaker
265 VOLT 9,000/12,000 BTUh 18,000 BTUh*
POWER
CONNECTION KIT
RAK515D RAK520D RAK530D RAK520D RAK530D
Heater BTUh 8360 11770 17060 11770 17060
Total Watt s 2568 3568 5118 3568 5118
Heater Watts 2450 3450 5000 3450 5000
Total Heating Amps 9.2 13 18.9 13 18.9
MCA
15
20 30
20 30
Recommend
Protective Device
(MOCP)
15 amp
time-delay
fuse or breaker
20 amp
time-delay
fuse or breaker
30 amp
time-delay
fuse or breaker
20 amp
time-delay
fuse or breaker
30 amp
time-delay
fuse or breaker
The correct kit for the installation is determined by the voltage and breaker size of the electrical circuit
*There is no 15 amp breaker option available for the 18,000 BTUh models due to compliance with UL standard 60335-2-40
Specifications subject to change without notice.