AUXILIARY CONTROLS
The electronic control for the unit comes preset from the factory to control the unit how “most” customers would
prefer the unit to operate. The presets (called modes or functions) can be modified to accommodate for differences
in installation parameters or personal preferences on how the unit should operate and perform.
If the owner modifies the auxiliary controls it is then the owner that is responsible for ensuring the auxiliary controls
are set to the desired function.
Modes of the Auxiliary Control
Mode 1 – Not Applicable
Mode 2 – Not Applicable
Mode 3 – Freeze Sentinel/Heat Sentinel
Mode 4 – Constant ON Fan
Mode 5 – Not Applicable
Auxiliary Set Mode
Mode 6 – Not Applicable
Mode 7 – Fan Boost Mode
Mode 8 – All Electric Heat (AZ95H only)
Mode 9 – Heat Boost (AZ95H only)
To change operating or set up parameters the control must be in AUX Mode. With power applied to the unit, press the
AUX SET button until the
“
“
appears on the display.
The display will look like this when entering the AUX Mode :
Aux
Set
+
Mode
–
While in AUX Mode, press the MODE button to scroll through the dierent modes. Continue the press the
MODE button until the number corresponding to the mode to be modified is showing in the first digit of the display.
Once the correct number is displayed, use the +/- buttons to change the second digit of the display for that mode
to either
“
“
for On OR
“
“
for O depending on the desired function.
When the selection for a given mode is complete press the MODE button to continue setting other auxiliary control
functions OR press the AUX SET button to confirm the selection and exit AUX SET mode.
SETTING THE AUXILIARY CONTROL
Auxiliary Controls-Aux Set Button