Dryer Specifications

GTD42GASJ
GE
Appliances Series 7.2 Cu. Ft. Capacity Gas Dryer
For answers to your Monogram, GE Café
Series, GE Profile
Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center
®
Service, 800.626.2000.
Specification Revised 5/16
EXHAUST OPTION: When viewed from the front of the
unit, exhaust 3-way via rear, left and bottom. Dryer is shipped
exhausted to the rear. Alternate exhausting knockouts
are supplied.
GAS: An individual, properly-grounded branch circuit, with
a three-prong grounding-type receptacle, protected by a 15
or 20 amp circuit breaker or a time-delay fuse is required.
GAS DRYER ELECTRIC RATING: 120V, 60Hz, 6A
GAS (BTU/HR): 22,000. Factory-equipped for natural gas.
Tested for LP gas. LP gas supply requires a conversion kit.
Check installation instructions for correct kit and have a
qualified gas technician install a conversion kit. See dryer
ducting information for proper installation.
NOTE: Dryer wall outlet must be located within 36" of service
cord entry and accessible when dryer is mounted in position.
INSTALLATION INFORMATION: For complete information,
see installation instructions packed with your dryer.
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES) SPECIAL INSTALLATION REQUIREMENTS
ALCOVE OR CLOSET INSTALLATION:
- If your dryer is approved for installation in an alcove or closet, it will be stated
on a label on the dryer back.
- The dryer MUST be exhausted to the outside.
- Minimum clearances between dryer cabinet and adjacent walls or other
surfaces are: 0" either side; 1" front, top and rear.
- Closet doors must be louvered or otherwise ventilated and must contain a
minimum of 60 sq. in. of open area equally distributed. If this closet contains
both a washer and a dryer, doors must contain a minimum of 120 sq. in. of
open area equally distributed.
- No other fuel-burning appliance shall be installed in the same closet
with a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
- The dryer MUST be exhausted to the outdoors.
- The installation must conform with the local codes, or in the absence
of local codes, with the National Electric Code and National Fuel Gas
Code, ANSI Z223 for gas dryers.
MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET
INSTALLATION:
- Minimum clearances to combustible surfaces are: 0" both sides; 1" rear.
DRYER EXHAUSTING INFORMATION : Use metal duct only, vertical
and horizontal ducting.