DimenSionS anD inSTallaTion informaTion
Cabinet 30"
A – Overlap of oven at top of cutout 1"
B – Overlap of oven over side of edges of cutout 3/4"
C – Overlap of oven at bottom of cutout 1"
Oven
D – Install depth 23-1/2"
E – Overall height with trim 43-3/8"
F – Overall width 29-3/4"
21" minimum
door opening
allowance
Conduit
48"
C
L
Suitable
bracing
to support
runners
2 x 4 or
equivalent runners
level with bottom of cutout
and ush with sides of cutout
or solid bottom oor.
B
30 ''
A
C
Cutout width
28-1/2" MIN.
28-5/8" MAX.
Recommended
minimum
cutout location
from the oor
21-5/8"
CT9800
PT9800
PT7800
JT3800
21"
E
F
D
Cutout height
42-3/16" MIN.
42-1/4" MAX.
ATTENTION INSTALLER:
All electric wall ovens must be hard-wired (direct-wired)
into an approved junction box. A plug and receptacle is NOT permitted on these products.
NOTE: If the cabinet does not have a solid bottom,
two braces or runners must be installed to support
the weight of the oven. For single ovens, the runners
and braces must support 200 lbs (91 kg). For double
ovens, the runners and braces must support 375 lbs.
(170 kg).
NOTE: If marks, blemishes or the cutout opening are
visible above the installed oven, it may be necessary
to add wood shims under the runners and front trim
until the marks or opening are covered.
NOTE: If the cabinet does not have a front frame
and the sides are less than 3/4" (1.9 cm) thick, shim
both sides equally to establish the cutout width.
9-1/2"
MAX.
Right side only
28" MIN. to
bottom of
junction box
Cutout depth
23-1/2"
MIN.
Junction box
location
(Junction box
may be located
in adjacent
cabinet)
Note: Cabinets installed adjacent to wall
ovens must have an adhesion spec of at
least a 194°F temperature rating.
Installation Information: Before installing,
consult installation instructions packed with
product for current dimensional data.
Door handle protrudes 3" from door face.
Cabinets and drawers on adjacent 45°
and 90° walls should be placed to avoid
interference with the handle.
Electric wall ovens are not approved for
installation with a plug and receptacle.
They must be hard wired in accordance
with installation instructions.
Note: These ovens are not
approved for stackable or side-by-
side installations.
Ct9800
KW RatiNg
240V 7.5
208V 5.7
BReaKeR Size
240V 40 Amps
208V 40 Amps