Installation Instructions 36” Rangetop 49-85219 06-14 GE
Safety Information BEFORE YOU BEGIN Vent hood Combinations: Read these instructions completely and carefully. • It is recommended that these rangetops be installed in conjunction with a suitable overhead vent hood. • Install a hood with at least 1200 CFM above a 48” wide rangetop. • Install a hood with at least 600 CFM above a 36” rangetop. Due to the high heat capacity of this unit, particular attention should be paid to the hood and ductwork installation to assure it meets local building codes.
Design Information CONTENTS Installation Instructions Step 1, Cut the Countertop Opening ..............................9 Step 2, Install the Rangetop ............................................10 Step 3, Connect Rangetop to Gas ................................10 Step 4, Connect Electrical.................................................11 Step 5, Check Burners .......................................................11 Finalize Installation ..............................................................
Design Information PRODUCT DIMENSIONS AND CLEARANCES FOR 48” MODELS 27-1/2” to Front of Bullnose 47-7/8” Width Universal Utility Locations Locate gas inlet on back wall or on floor 2” from back wall. 8-1/2” Height 48” Minimum to Combustibles 2” 17” 16” 12” Minimum to Adjacent Wall WARNING: Installations without a hood require 48” minimum to combustibles above the rangetop. A custom hood installation with exposed horizontal combustible surfaces must have an Auto-On feature.
Design Information PRODUCT DIMENSIONS AND CLEARANCES FOR 36” MODELS Universal Utility Locations 35-7/8” Width 27-1/2” to Front of Bullnose 2” 17” Locate gas inlet on back wall or on floor 2” from back wall. 8-1/2” Height 16” 48” Minimum to Combustibles 12” Minimum to Adjacent Wall WARNING: Installations without a hood require 48” minimum to combustibles above the rangetop. A custom hood 13” Max. installation with exposed horizontal combustible surfaces must have 18” Min. an Auto-On feature.
Design Information INSTALLATION OPTIONS Finished back edge of control panel 8” Countertop Level † Back edge of chamfer * ** Include the overhang of the rear trim when countertop continues behind the product. The overhang is decorative only. The weight of the rangetop is fully supported by the side trims. † ** Maximum countertop cutout depth from the back of the rear trim to the back edge of chamfer at the sides of the control panel - typically, the maximum countertop cutout depth (front to back).
Installation Preparation TOOLS REQUIRED MATERIALS PROVIDED Saber Saw Drill and Appropriate Bits Measuring Tape Adjustable Wrench Hold-Down Strap Regulator MATERIALS REQUIRED (not provided) 1/4” Driver or Wrench Carpenter’s Square Joint Sealant Pipe Fittings Shut-Off Valve Safety Glasses 5-foot maximum length, 5/8” O.D. CSA-approved flexible metal gas supply (3-foot maximum length in Massachusetts only) NOTE: Purchase new flexible line; do not use previously used flexible gas line.
Installation Preparation REMOVE PACKAGING CAUTION • Cut the ties holding the grill grate to the grill frame. Griddle Flue Cover Stand clear. The ends of the cut metal banding may snap toward you. • Cut the metal banding. • Remove packaging tape and foam. Dispose of packaging materials properly. • Remove grill/griddle covers, grill grate and burner grates. Ties Grease Troughs • Lift out cast-iron griddle flue cover, grease troughs and pads.
Installation STEP 1 CUT THE COUNTERTOP OPENING 48” wide models are designed to fit in 48” or wider base cabinets 36” wide models are designed to fit in 36” or wider base cabinets Cutout Opening with False Bottom Measure carefully when cutting the countertop. Make sure sides of the opening are parallel. • Allow 8” free space below the top surface of the countertop. • Allow additional clearances below the burner box to install the regulator and make house supply connections.
Installation STEP 2 INSTALL RANGETOP • Slide the rangetop into the opening. Make sure the rangetop is evenly seated and supported. • A hold-down strap with screws is provided to secure the rangetop to the rear or side cabinet walls. • Remove the hold-down strap from the back of the rangetop. Attach one end of the strap to the back of the rangetop. • Secure the other end of the strap as high as possible to the cabinet back wall or adjacent cabinet. Keep the strap as short as possible for better security.
Installation STEP 4 CONNECT ELECTRICAL FINALIZE INSTALLATION • Plug power cord into properly grounded receptacle. Place the burner grates over the burners. The grates should be seated and should not rock. • Press the button on the left side of the control panel. The lights above the knobs should illuminate. The griddle is secured with screws. It is designed to be stationary and should not be removed.
ZX12B30PSS, ZX12B36PSS, ZX12B48PSS Accessory Installation 237,21$/ $&&(6625,(6³ ” HIGH BACKSPLASH WARNING: INSTALL 12” BACKSPLASH WARNING: To prevent ignition of combustible materials, the entire back wall above the range must be protected by a backsplash constructed of noncombustible material. This backsplash must be securely fastened to the wall. Failure to do so could result in damage or personal injury.
ZXADJB30PSS, ZXADJB36PSS, ZXADJB48PSS Accessory Installation $&&(6625,(6³ ” TO 36” ADJUSTABLE BACKSPLASH (not included) INSTALL THE WALL SUPPORT PANELS WARNING: WARNING: To prevent ignition of combustible materials, the entire back wall above the range must be protected by a backsplash constructed of noncombustible material. The wall support panels must be securely fastened to the wall. Failure to do so could result in damage or personal injury.
ZXADJB30PSS, ZXADJB36PSS, ZXADJB48PSS Accessory Installation INSTALL COVER PANELS INSTALL COVER PANELS (cont.) See alternate method if side access is blocked. ALTERNATE METHOD: When side access is blocked • Hold the bottom cover over the bottom support while driving one screw (provided) into each side. • Place the top cover with shelf over the top wall support. If you have access to the sides, secure the panel with two screws on each side.
Convert Natural Gas to LP Gas Operation Convert LP Gas to Natural Gas Operation 2 CONVERT THE REGULATOR WARNING: This conversion must be Disconnect all electrical power at the main circuit breaker or fuse box. A. Remove the rear vent Range Regulator trim (on ranges only) to access the regulator. performed by a qualified installer or gas supplier in accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction.
Installation Instructions for Gas Conversion 3 CHANGE BURNER ORIFICES (cont.) 4 ** CHANGE GRILL ORIFICE (cont.) IMPORTANT: Find your model number below. Read each orifice label to identify and install them in the exact locations shown. ZDP304 SIMMER ORIFICES A. Remove the grill cover, grates and grate frame. Lift the radiant baffle straight up and off. B. Remove the 2 hex head screws from the top of the igniter. • Remove one screw from each side of the burner surround. • Lift out the surround.
Installation Instructions for Gas Conversion 5 CHANGE GRIDDLE ORIFICE (if present) 6 ADJUST BURNER FLAMES Locate the 3/4” long griddle orifice. Select for your gas type. LP³.047, NAT³.076 Normally, burners do not need further adjustment. Make adjustments only when necessary. A. Lift off the griddle flue A. Turn on the gas. Plug in electrical cord. B. Turn all burners on highest setting and check the flames. They should be blue in color.