User guide

WintDrive
Parameters
name
offset
tme
illt
alternative
type
function
8192 Offset to be summed to the parameter identifiers
iDaO..iDa4.
ipa
ipal
hit
iut
0
Identifier of the DRIVE parameter that will be
found in slot 0 of the communication structure.
0
Identifier of the DRIW parameter that will be
found in slot 1 of the communication structure,
ipa
ipa
int
illt
0
Identifier of the DRIVE parameter that will be
found in slot 2 of the communication structure.
0
Identifier of the DRIVE parameter that will be
found in slot 3 of the communication structure.
ipa
int
0
Identifier of the DRIVE parameter that will be
found in slot 4 of the communication structure.
wo142
The DGFC board communicates to the DRIVE through a device called DPRAM. This device allows the
DGFC card to write or read from the parameters of the DRIVE, and consequently to condition its functioning.
In DPRAM there are various communication structures with different functioning modes.
The structure piloted by the IDS block carries out a reading operation of DGFC from the DRIVE parameters.
The maximum number of parameters to be controlled by this structure is 5. The reading of the parameters
occurs at the beginning of each regulation cycle.
The communication structure is composed of five slots. Inside each slot 3 data are contained:
IPA Identifier of DRIVE parameters
TYPE Type of DRIVE parameters
VALUEValues to be read from parameter specified by lPA
During the transition of DGFC from
IDLE-SEADY
the communication structure is configured:
DGFC copies lPAO..lPA4 parameters in the lPA field of the respective slots.
DGFC requires the DRIVE to carry out the configuration of the communication structure.
The DRIVE analyses the parameter identifiers in the lPA field and if it finds them in compliance with each
other, it writes the type of the required parameter in the TYPE field. The TYPE field will be used during the
communication to perform the automatic conversion of data.
If any parameter identifier does not comply with the others, the whole communication structure will be
disabled and the output port in RUN will contain value 0.
After performing the configuration of the communication structure, DGFC reads the VALUE field of each slot
and copies it in the output ports vO..v4. This operation is carried out periodically by DGFC before starting a
regulation cycle.
The offset parameter is summed to ipaO..ipa4 parameters, this permits to refit the parameter identifiers.