User's Manual

MDS 05-3447A01, Rev. F MDS 1710A/C and MDS 2710A/C/D 19
3. Set up the HHT as listed in Table 6.
5.3 Keyboard Commands
Table 7 is a reference chart of software commands for the transceiver.
Programmable information is shown in brackets [ ] following the com-
mand name. See
Section 5.4, Detailed Command Descriptions for
detailed command descriptions.
Entering Commands
To enter a command, type the command, followed by an key-
stroke. For programming commands, the command is followed by
and the appropriate information or values, then
.
Here are some additional points to remember when using the HHT:
Use the key to access numbers; press again to return to letter
mode.
Use the key to edit information or commands entries.
The flashing square cursor ( ) indicates that letter mode is
selected.
The flashing superscript rectangular cursor ( ) indicates that
number mode is selected.
Error Messages
Listed below are some possible error messages that may be encountered
when using the HHT:
UNKNOWN COMMAND—The command was not recognized. Refer to the
command description for command usage information.
INCORRECT ENTRY—The command format or its associated values were
not valid. Refer to the command description for command usage infor-
mation.
Table 6. HHT Operational Settings
Parameter Setting Parameter Setting
Re-init HT NO Scroll On 33rd
Baud Rate 9600 Cursor ON
Comm bits 8,1,n CRLF for CR OFF
Parity Error OFF Self Test FAST
Key Repeat OFF Key Beep ON
Echo OFF Screen Size 80
Shift Keys YES Menu Mode LONG
Ctl Chars PROCS
ENTER
SPACE
ENTER
SHIFT
ESC/BKSP