User's Manual

24 TransNET OEM Integration Guide 05-3946A01, Rev. C
Modem will echo characters in the data stream but will be ignored until a
second “AT” is seen at which time the modem closes the virtual
connection.
Operating Notes when AT Commands are ON
Radios will not poll with the embedded RTU simulator unless a
connection is established.
Network-wide diagnostics are unaffected by the dialed unit connection
status.
The use of the TransNET
OT command (Output Trigger) can be of
benefit in some configurations. See “OT [ON, OFF]” on Page 49 for
configuration details.
6.5 Configuration Parameters for Store & Forward
Services
The installation and configuration of a radio network with an Extension using
SAF is straightforward with only a few unique parameters that need to be
considered and set at each unit.
In every network there can be only one Master station. It will serve as the sole
gateway to the outside world. The following three tables detail the parameters
that will need to be set on each type of radio in the network.
Network Master Radio—Table 7 on Page 24
Extension Radio(s)—Table 8 on Page 25
Remote Radio(s)—Table 9 on Page 26
Table 7. Configuration Parameters for SAF Services
Network Master Radio
Parameter Command Description
Operating Mode
MODE M
Details Page 48
Sets the radio to serve as a
Master.
Network Address
ADDR
Details Page 40
A number between 1 and
65,000 that will serve as a
common network address.
All radios in the network use
the same number.