User's Manual

05-3946A01, Rev. C TransNET OEM Integration Guide 35
Table 13. Network Configuration—Master Station
COMMAND DESCRIPTION
AT [ON, OFF]
Details Page 41
Enables Master station to emulate a modem and
respond to AT commands
BUFF [ON, OFF]
Details Page 42
ON = Seamless data
OFF = Fast byte throughput.
FEC [ON, OFF]
Details Page 45
Sets/disables FEC
(Forward Error Correction) setting.
HOPTIME [7, 28]
Details Page 45
Displays hop-time or sets it to 7 or 28 ms.
LPM [1, 0]
Details Page 47
Used at Master to set all associated stations in an
energy-conservation mode.
1 = Low-power mode enabled network-wide
0 = Disable low-power mode (Default)
REPEAT
Details Page 50
Sets/displays the fixed downstream re-send count.
RETRY [0–10]
Details Page 50
Sets/displays the maximum upstream re-send
count for ARQ (Automatic Repeat Request) opera-
tion
SAF [ON, OFF]
Details, page 52
Enables/disables the store-and-forward function
for the network controlled by this Master unit.
SKIP [NONE, 1...8]
Details, page 53
Skip one or more frequency zones
Table 14. Network-Wide Diagnostics
Command Description
DLINK [xxxxx/ON/OFF]
Details, page 44
Controls operation of diagnostic link function.
DTYPE [NODE/ROOT]
Details, page 45
Set radio’s operational characteristics for
network-wide diagnostics