User's Manual

36 TransNET OEM Integration Guide 05-3946A01, Rev. C
Table 15. Operational Configuration—Set/Program
Command Description
ADDR [1–65000]
Details, page 40
Program network address
AMASK [0000 0000–FFFF FFFF]
Details, page 41
Alarm response
Default: FFFF FFFF
ASENSE [HI/LO]
Details, page 41
Sense of the alarm output on Pin 6 of the INTER-
FACE connector in the EIA-232 mode. Default:
Alarm present = HI
BAND [A, B, C]
Details Page 42
Selects one of three operating bands.
(2.4 GHz Model Only)
BAUD [xxxxx abc]
Details, page 41
Data communication parameters
CODE [NONE, 1…255]
Details, page 42
Select the security/encryption setting in the radio
CSADDR [1–65000, NONE]
Details, page 43
Used on a single Master/Remote network to sup-
port TDD-style simulated full-duplex.
CTS [0–255]
Details, page 43
CTS delay in milliseconds
(A value of 0 returns CTS immediately)
CTSHOLD [0–60000]
Details, page 43
“Hold time” that CTS is present following last
character from DATA port.
DEVICE [DCE, CTS KEY]
Details, page 44
Device behavior:
DCE (normal) or CTS Key
MODE [M, R, X]
Details, page 48
Operating mode:
M = Master, R = Remote, X = Extension
MRSSI [NONE, –40...–90]
Details, page 48
Minimum RSSI level required to preserve syn-
chronization with a Master radio for Remotes in
mobile service.
OT [ON, OFF]
Details, page 49
Enables a 1-second delay on delivery of RXD
serial data.
OWN [xxxxx]
Details, page 49
Owner’s name, or alternate message
(30 characters maximum)
PORT [RS232, RS485]
Details, page 49
Data port (DATA connector) interface
signaling mode: RS232 or RS485
PWR [20–30]
Details, page 49
Power output in dBm
(Figure 35 on Page 84)
RXD [0–255]
Details, page 51
Set RXD delay time for virtual seamless mode
with low latency