05-3946A01, Rev. C TransNET OEM Integration Guide 79
Invisible place holder
Figure 24. Evaluation PCB’s DATA Interface, J5,
Unterminated Pins Eyelets
PCBs 03-4051A01, Rev. B and later
Transceiver Power Interface, J1
Terminal block, J1, on the Evaluation PCB, provides direct access to the two
power lines feeding the transceiver module—unregulated primary power
(6–30 Vdc) and regulated 3.3 Vdc.
These jumpers and nearby eyelets can be used for two functions: 1. Measure
the module current consumption under various operating conditions by
inserting an inline ammeter, and 2. To bypass the Evaluation PCB’s 3.3 Vdc
regulator to connect your own power source.
With the jumpers removed, the pins of J1 can be used as convenient points to
measure the regulated and unregulated power supplied to the OEM module.
Invisible place holder
Figure 25. J1, Transceiver Power Eyelets
NOTE: Jumper J1 does not normally require any change by the user for basic
operation of the transceiver module on the Evaluation PCB.Both jumper
plugs are normally installed on J1.
H11 / J5-1
H12 / J5-6
H14 / J5-9
H13 / J5-4
J5
6–30 V DC
POWER IN
H15 / J1-2
6–30 V DC
POWER LOAD
H21 / J1-3
3.3 V DC
POWER LOAD
H22 / J1-1
3.3 V DC
POWER IN
H17 / J1-2
J5