User's Manual
TRAIN CHIEF® II LRCS w/Lightweight OCU OWNER’S MANUAL
95-00-0-xxx Rev 000 3-14 Control Chief Corporation
Manual/Remote Transfer Switch Selections and Functions
Function
Manual
(CAB)
Remote Comments
Strobe
OUT
IN
Strobe active ONLY in remote mode
Ignition Wire IN OUT Disables engine start when in remote
mode.
Throttle Switch IN OUT Disables manual throttle lever in remote
mode.
Head Light IN OUT Disables manual headlight switch in
remote mode.
Reverser IN OUT Disables reverser lever in remote mode.
Dedicated Locomotive Hook-Ups
Locomotive connections to the locomotive interface panel are accomplished through the bottom
of the panel via dedicated locomotive hookups. These hookups consist of connector sockets
based on system options to facilitate ease of installation.
¾ The pneumatic connections are located on the bottom left of the panel, and include quick
connect ports for main air, locomotive brake, train brake, and bail.
¾ The rectangular connector is for the general locomotive interface cable. The cable is 30-
conductor with a strain relief.
¾ The round connector(s) are for specific functions such as external E-Stop, strobe status
lights, and other optional features.
Refer to system prints, drawing E-9668-03-01 for more application specific details. Refer to
Figure 6-7 for detailed pneumatic interface diagram. Always refer to your system prints for