Filter bowls are fitted with automatic drains to drain accumulated liquids to minimize
maintenance and insure optimum performance.
Filter Installation and Maintenance
Flush piping before installation. To maintain maximum efficiency of the filter and to avoid
excessive pressure drop the filter must be kept clean. Removal (of filter assembly) from
operation is not necessary to clean the filter. Disassembly is simple and can be performed
inline. Before disassembling, shut off air supply and depressurize the filter. Clean all parts
(except filter element) with mild non-abrasive soap and blow out filter body before reassembling.
Lithium-Ion Battery Maintenance
The Lithium battery is the primary power source for Control Chief remote control OCUs. Proper
care and maintenance will assure optimum performance of the batteries in all applications. The
battery pack used in the Lightweight OCU is 7.4 VDC and has a typical application time of 12
hours (based on full capacity charge).
Battery Care Summary
¾ For optimum battery performance, only recharge the battery pack when the OCU’s
low battery indicator has activated.
¾ Do not leave the OCU on for extended periods of time.
¾ Do not charge in an area where the temperature is over 75
o
F.
¾ Do not subject the battery to physical abuse such as dropping it or placing it on hot
objects such as ovens, forges, etc.
¾ Do not short the battery connection together. Injury may occur.
¾ Always follow proper battery handling and disposal procedures. Always follow all
manufacture instructions.
¾ Do operate the OCU until the low battery indicator activates. Do not plan to operate
the OCU for any extended time once the low battery indicator has activated.
OCU Operating Duration per Battery Charge
The Lightweight OCU and battery pack have been designed to give a minimum of 12-hours of
continuous operation for the typical operating environment.
Conditions that will degrade the daily capacity (run time) of the battery pack are, charging in
high temperatures, operating in cold temperatures (below 32
o
F), and constant re-charging.
Battery Disposal