User Manual

MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide (Preliminary) 115
6.1 REMOTE TRANSCEIVER
COMMAND REFERENCE
6.1.1 Command Description
The following commands are used to set the configuration and operating
parameters for the MDS entraNET radio...They can be issued from a
console terminal connected as shown in Section...
HELP
Lists the commands available through the console interface.
HELP DUMP TOR RADIO
LOGIN AUTH BOOT DATE
COM1 CONSOLE PAYLOAD OEM
REG POWER WAKE TREND
ENCRYPT REPROG H2H VER
DEVICE CONFIG CONFIGTAB IMAGE
DUMP
Lists the current value of all variables.
TOR
Syntax: TOR [optional arguments as follows]...
<COMMAND> command string to send to TOR
PASS=<choices>
0 ;COM2 passthrough to/from TOR LCP data port DISABLED
1 ;COM1 passthrough to/from TOR diagnostic port
2 ;COM2 passthrough to/from TOR LCP data port
REPROG=<choices>
0 ;reprogram tor with image for currently executing OIB image.