66 MDS entraNET 900 System Guide (Preliminary) MDS 05-4055A01, Rev. A
The maximum number of remotes allowed to connect to this Access
Point.
Device Mode: Access Point
Configures the unit to act as a Remote or an Access Point. The
Access Point option is not allowed unless the unit is specifically
ordered as such, or an Authorization Key has been purchased to
allow it.
Dwell Time: 32.8
The amount of time the unit spends at any given frequency in its
hopping pattern. This field is only changeable by an Access Point.
Remotes read the Masters value upon association.
Hop Pattern: 1
RSSH Calibration: 235
RSSL Calibration: 190
Freq Calibration: 8402
Network Name: West Campus Net
The name of the network this unit belongs to. The unit will only
communicate with devices having identical Network Names.
Date Format: Generic
Specifies the format of the date.
Generic = dd Mmm yyyy
European = dd-mm-yyyy
US = mm-dd-yyyy
Console Baud: 19200
The baud rate of the serial menu console. Default value is
19200 bps.
Company Name: MDS
Version Name: 06-1234567
Product Name: entraNET
Beacon Period: Normal
The amount of time in milliseconds between beacon transmissions
by the AP.
Data Rate: 115.2 kbps
The selected over-the-air data rate. A lower data rate generally
allows more distance between the unit and its Access Point.
RF Output Power Setpoint: 30
The desired amount of RF output power, measured in dBm.
Power Cal Table DAC1: 98
21 additional values follow; do not alter
Active Boot Image: 0