MDS 05-4055A01, Rev. A MDS entraNET 900 System Guide (Preliminary) 93
*Condition may be corrected by user and alarm cleared.
4.1.5 Correcting Alarm Conditions
(See View Event Log on Page 49)
Table 4-6 provides insight on the causes of events that inhibit the unit
from operating, and possible corrective actions The Event Description
column appears on the
Event Log screen.
EVENT_MAC MAC communication
Failed
macCommunication(1)
EVENT_MACADDR MAC Address Invalid noMacAddress(6)
EVENT_NETNAME
*
Netname Invalid invalidNetname(12)
EVENT_PLL_LOCK PLL Not locked pllLock(10)
EVENT_POWER_CAL Power Calibrated/Not
Calibrated
powerCal(8)
EVENT_POWER_HIGH RF Power Control
Saturated High
rfPowerHigh(13)
EVENT_POWER_LOW RF Power Control
Saturated Low
rfPowerLow(14)
EVENT_RSSI
*
RSSI Exceeds
threshold
rssi(11)
EVENT_RSSI_CAL RSSI Not Calibrated rssiCal(9)
EVENT_SYSTEM_ERROR* System Error Cleared;
Please Reboot
systemError(16)
Table 4-5. Alarm Conditions (Alphabetical Order) (Continued)
Alarm Condition Reported Event Log Entry SNMP Trap
Table 4-6. Correcting Alarm Conditions
(Alphabetical Order)
Event Log Entry Generating Condition Clearing Condition
or Action
ADC Failure The ADC always reads the
same value (either high or
low limit)
Contact MDS Technical
Services for assistance
AP Ethernet Link Monitor will check state of
Ethernet link and set alarm if
it finds the link down
Ethernet link is re-established
Bridge Down When the Bridge fails to be
initialized
Contact MDS Technical
Services for assistance
Flash Test Failed Internal check indicates
corruption of Flash memory
Contact MDS Technical
Services for assistance
FPGA Failure Communication lost to the
FPGA
Contact MDS Technical
Services for assistance
General System
Error
Internal checks suggest unit
is not functioning properly
Reboot the transceiver
Initialization Error Unit fails to complete boot
cycle
Contact MDS Technical
Services for assistance