88 MDS entraNET 900 System Guide (Preliminary) MDS 05-4055A01, Rev. A
resolving common system difficulties using the LEDs, and Table 4-2
other simple techniques.
4.1.2 Troubleshooting Using the Embedded
Management System
If you have looked over and tried the things mentioned in Table 4-1and
still have not resolved the problem, there are some additional tools and
techniques that can be used. The embedded Management System is a
good source of information that may be used remotely to provide pre-
liminary diagnostic information, or may even provide a path to cor-
recting the problem.
Table 4-1. Troubleshooting Using LEDsSymptom-Based
Symptom Problem/Recommended System Checks
PWR LED does not
turn on.
a. Voltage too lowCheck for the proper supply voltage at
the power connector. (10.530 Vdc)
b. Indefinite ProblemCycle the power and wait
( 30 seconds) for the unit to reboot. Then, recheck for
normal operation.
LINK LED does not
turn on.
a. Network Name of Remote not identical to desired Access
PointVerify that the system has a unique Network Name.
b. Not yet associated with an Access Point with the same
Network Name.
Check the Status of the units process of associating with
the Access Point. Use the entraNET Management System.
c. Poor Antenna SystemCheck the antenna, feedline and
connectors. Reflected power should be less than 10% of
the forward power reading (SWR 2:1 or lower).
PWR LED is
blinking.
a. Blinking indicates an alarm condition exists.
b. View Current Alarms and Event Log and correct the
problem if possible.
(See “Using Logged Operation Events” on Page 92)
c. Blinking will continue until the source of the alarm is
corrected, for example, a valid IP address is entered, etc.
LAN LED does not
turn on.
a. Verify the Ethernet cable is connect at both ends.
b. Verify that the appropriate type of Ethernet cable is used:
straight-through, or crossover.
Table 4-2. Basic Troubleshooting with the entraNET MS
Symptom Problem/Recommended System Checks
Remote does not
associate; stays in
HOPSYNC
a. Verify the AP has sufficiently large number in the Max
Remotes parameter of the Network Configuration Menu.
b. Verify the correct MAC address is listed in the Approved
Remotes List or Approved Access Points List of the
Security Configuration menu.
Serial data is slow
with UDP multicast
traffic
a. Change Beacon Period to FAST.
(Radio Configuration Menu)