User's Manual

24 MDS Mercury 16E Technical Manual MDS 05-6302A01, Rev. A
Invisible place holder
Figure 14. Setup Wizards—Serial Configuration
To begin the Serial Wizard, click the Begin Wizard link under the Serial
Wizard table.
The wizard prompts for the protocol to configure. The options are TCP,
UDP, or TCP/MODBUS.
Example: TCP Server
The following procedure describes how to setup a TCP Server.
1. Select TCP as the IP protocol.
2. Select the desired TCP mode - client or server or client/server.
3. Next, specify the local port to use for receiving TCP data from the
host. Click
Continue Wizard to continue.
4. Specify the buffer size and inter-packet delay, then click Continue
Wizard
.
5. Choose whether to enable or disable COM1 for communication. If
Enable is selected, COM1 operates as a TCP Server as soon as the
Serial Wizard is complete. If
Disable is selected, the settings are
saved upon completion of the Serial Wizard, and
COM1 may be
enabled for data transfer at a later time in the Serial Configuration
main page. Click
Continue Wizard to continue.