Table 6 provides a description for each of the above parameters.
Quality of Service (QoS) Screen
The transceiver's Configuration - QoS page displays the active service
flows as well the user-configured flows.
Figure 17. Configuration-QoS Screen
(Active Service Flows)
Table 6. Parameter Descriptions
Parameter Description
Min Reserved Rate The minimum rate in bits per second that must be
reserved for the service flow. For UGS, the Min
Reserved Rate is set to the same value as the Max
Sustained Rate.
Max Sustained Rate The maximum rate in bits per second that the service
flow will increase to. It is used as an upper bound for
the flow.
Priority A value used to describe the priority between service
flows that have the same characteristics and settings.
Max Latency The maximum time between the reception of the
packet from the wire and its delivery to the other end
of the link.
Grant Interval The time period between successive grants by the
Base Station for a UGS or eRTPS service flow.
Polling Interval The time period between successive polls by the
Base Station for a RTPS or nRTPS service flow.