User's Manual
05-4446A01, Rev. C Mercury Reference Manual 71
¥ RX IP PortReceive IP data from this source and pass it
through to the connected serial device. The port number must
be used by the application connecting to local TCP or UDP
socket. [
Any valid IP port; 30010]
¥ TX IP Address (used instead of Local IP Address when using
UDP Point-to-Multipoint) Configure with a valid Multi-
cast address (224.0.0.0—239.255.255.255). IP packets
received with a matching destination address are processed
by this unit. [
Any legal IP address; 0.0.0.0]
¥ TX IP Port (used instead of Local IP Port when using UDP
Point-to-Multipoint)This port number must match the
number used by the application connecting to local TCP or
UDP socket. [
1-64,000; 30010]
¥ Baud RateData rate (payload) for the COM port, in
bits-per-second. [
1,200—115,200; 19200]
¥ Byte FormatFormatting of data bytes, representing data bits,
parity and stop bits. [
7N1, 7E1, 7O1, 8N1, 8E1, 8O1, 8N1, 7N2, 7E2,
7O2, 8N2, 8E2, 8O2; 8N1
]
¥ Buffer SizeMaximum amount of characters that the Remote
end buffers locally before transmitting data through the serial
port. [
1—255; 255]
¥ Inter-Packet DelayAmount of time that signal the end of a
message, measured in tenths of a second. [
default = 1 (that is,
1/10th of a second)
]
¥ Commit Changes and Exit WizardSave and execute changes
made on this screen (shown only after changes have been
entered).
Invisible place holder
Figure 3-35. UDP Point-to-Point Menu
Configuring for UDP
Point-to-Point
Use UDP point-to-point configuration to send information to a single
device.
¥
StatusEnable/Disable the serial data port.