User's Manual
116 Mercury Reference Manual 05-4446A01, Rev. C
¥ Image CopyInitiate the copying of the active firmware into the
inactive image.
¥
Reboot DeviceInitiates rebooting of the transceiver. This will
interrupt data traffic through this unit, and the network if per-
formed on an Access Point. Intended to be used for switching
between firmware images 1 and 2.
¥
Current FirmwareDisplays the versions of firmware images
installed in the transceiver and shows whether Image 1 or Image
2 is currently active.
NOTE: See Upgrade Procedure on Page 117 for details on setting up
the TFTP server.
Firmware images are available free-of-charge at:
www.GEmds.com/Resources/TechnicalSupport/.
NOTE: You may not install AP firmware in Remote radios, or
vice-versa. This was only true for earlier (pre-2.1.0) firmware.
To install firmware by TFTP, you will need:
¥ A PC with a TFTP server running
¥ The IP address of the PC running the TFTP server
¥ A valid firmware file
The IP address of the radio can be found under the Management
Systems
Starting Information Screen. (
See Starting Information Screen
on Page 40
.)
A TFTP server is available on the GE MDS Web site at:
www.GEmds.com/Resources/TechnicalSupport/.
TIP: If you do not know your computers address on a Windows PC, you
can use the
RUN function from the Start menu and enter winipcfg or
ipconfig to determine your local PCs IP address.
There are several alternatives to connecting the transceiver for firmware
upgrades.
Figure 3-90 and Figure 3-91 show two variations. It is essen-
tial that all equipment be on the same subnet.