User's Manual
05-4446A01, Rev. C Mercury Reference Manual 163
• Sensitivity and Data Rate (see chart below):
* The transceiver is a half-duplex radio, so maximum user throughput is
based on a configured or dynamic duty cycle, which is typically 50/50
indicating that half of the maximum throughput would be available one
way. The maximum user throughput is also based on high protocol over-
head from TCP/IP applications. For UDP applications, these throughput
numbers will increase.
Physical Interface
• Ethernet: 10/100BaseT, RJ-45
• Serial: 1,200 – 115,200 bps
• COM1: RS-232, DB-9F
• Antennas: TX/RX–TNC connector, GPS—SMA connector
• LED Indicators: PWR, COM1, LINK, LAN
Protocols (Pending—contact factory for details)
• Ethernet: IEEE 802.3, Spanning Tree (Bridging), VLAN, IGMP
• TCP/IP: DHCP, ICMP, UDP, TCP, ARP, Multicast, SNTP,
TFTP
• Serial: Encapsulation over IP (tunneling) for serial async multi-
drop protocols including MODBUS™, DNP.3, DF1, BSAP
GE MDS Cyber Security Suite, Level 1
• Encryption: AES-128.
• Authentication: 802.1x, RADIUS, EAP/TLS, PKI, PAP, CHAP
• Management: SSL, SSH, HTTPS
Management
• HTTP, HTTPS, TELNET, SSH, local console
• SNMPv1/v2/v3, MIB-II, Enterprise MIB
•SYSLOG
• MDS NETview MS™ compatible
Environmental
• Temperature: -40°C to +70°C (-40°F to +158°F)
• Humidity: 95% at 40°C (104°F) non-condensing
Modulation
(CP=1/16)
3.5 MHz Channel 1.75 MHz Channel
Sensitivity Signaling
Rate
Max. User
Throughput
(Aggregate)*
Sensitivity Signaling
Rate
Max. User
Throughput
(Aggregate)*
64 QAM 3/4 FEC -77 dBm 12.7 Mbps 7.2 Mbps -80 dBm 6.35 Mbps 3.6 Mbps
16 QAM 3/4 FEC -86 dBm 8.4 Mbps 4.8 Mbps -89.5 dBm 4.2 Mbps 2.4 Mbps
QPSK 3/4 FEC -92 dBm 4.2 Mbps 2.4 Mbps -95 dBm 2.1 Mbps 1.2 Mbps
BPSK 1/2 FEC -95 dBm 1.4 Mbps 500 Kbps -98 dBm 706 Kbps 250 Kbps