User's Manual

74 Mercury Reference Manual 05-4446A01, Rev. C
Buffer Size—Maximum amount of characters that the Remote
end buffers locally before transmitting data through the serial
port. [1–255; 255]
Inter-Frame Packet Delay—A measurement representing the
end of a message, measured in tenths of a second.
[default = 1 (that is, 1/10th of a second)]
Commit Changes and Exit Wizard—Save and execute changes
made on this screen (shown only after changes have been
entered).
Invisible place holder
Figure 3-37. TCP Server Menu (AP)
Status—Enable/Disable the serial data port.
IP Protocol—TCP Server. This is the type of IP port offered by
the transceivers serial device server.
[TCP, UDP; TCP]
Local Listening IP Port—Receive IP data from this source and
pass it through to the connected serial device. The applica-
tion connecting to the local TCP or UDP socket must use this
port number.
[Any valid IP port; 30010]
Baud Rate—Data rate (payload) for the COM port, in
bits-per-second. [1,200–115,200; 19200]
Byte Format—Interface signaling parameters. Data bits, parity
and stop bits.
[7N1, 7E1, 7O1, 8N1, 8E1, 8O1, 8N1, 7N2, 7E2, 7O2, 8N2, 8E2, 8O2;
8N1
]
Buffer Size—Maximum amount of characters that the Remote
end buffers locally before transmitting data through the serial
port. [1–255; 255]
Inter-Packet Delay—Amount of time that signal the end of a
message, measured in tenths of a second. [default = 1 (that is,
1/10th of a second)
]