User's Manual
05-4446A01, Rev. C Mercury Reference Manual 163
¥ Sensitivity and Data Rate (see chart below):
* The transceiver is a half-duplex radio, so maximum user throughput is
based on a configured or dynamic duty cycle, which is typically 50/50
indicating that half of the maximum throughput would be available one
way. The maximum user throughput is also based on high protocol over-
head from TCP/IP applications. For UDP applications, these throughput
numbers will increase.
Physical Interface
¥ Ethernet: 10/100BaseT, RJ-45
¥ Serial: 1,200 — 115,200 bps
¥ COM1: RS-232, DB-9F
¥ Antennas: TX/RX—TNC connector, GPSSMA connector
¥ LED Indicators: PWR, COM1, LINK, LAN
Protocols (Pendingcontact factory for details)
¥ Ethernet: IEEE 802.3, Spanning Tree (Bridging), VLAN, IGMP
¥ TCP/IP: DHCP, ICMP, UDP, TCP, ARP, Multicast, SNTP,
TFTP
¥ Serial: Encapsulation over IP (tunneling) for serial async multi-
drop protocols including MODBUS“, DNP.3, DF1, BSAP
GE MDS Cyber Security Suite, Level 1
¥ Encryption: AES-128.
¥ Authentication: 802.1x, RADIUS, EAP/TLS, PKI, PAP, CHAP
¥ Management: SSL, SSH, HTTPS
Management
¥ HTTP, HTTPS, TELNET, SSH, local console
¥ SNMPv1/v2/v3, MIB-II, Enterprise MIB
¥ SYSLOG
¥ MDS NETview MS“ compatible
Environmental
¥ Temperature: -40¡C to +70¡C (-40¡F to +158¡F)
¥ Humidity: 95% at 40¡C (104¡F) non-condensing
Modulation
(CP=1/16)
3.5 MHz Channel 1.75 MHz Channel
Sensitivity Signaling
Rate
Max. User
Throughput
(Aggregate)*
Sensitivity Signaling
Rate
Max. User
Throughput
(Aggregate)*
64 QAM 3/4 FEC -77 dBm 12.7 Mbps 7.2 Mbps -80 dBm 6.35 Mbps 3.6 Mbps
16 QAM 3/4 FEC -86 dBm 8.4 Mbps 4.8 Mbps -89.5 dBm 4.2 Mbps 2.4 Mbps
QPSK 3/4 FEC -92 dBm 4.2 Mbps 2.4 Mbps -95 dBm 2.1 Mbps 1.2 Mbps
BPSK 1/2 FEC -95 dBm 1.4 Mbps 500 Kbps -98 dBm 706 Kbps 250 Kbps