User's Manual Part 3
152 Mercury Reference Manual 05-4446A01, Rev. D
permanent memory (Flash memory) until cleared by user request.
Table 4-4 summarizes these classifications.
These events are stored in the transceiver’s Event Log and can be a valu-
able aid in troubleshooting unit problems or detecting attempts at
breaching network security.
4.1.4 Alarm Conditions
Most events, classified as “critical” will cause the PWR LED to blink,
and will inhibit normal operation of the transceiver. The LED blinks
until the corrective action is completed. (See also
Event Log Menu on
Page 112.)
Table 4-4. Event Classifications
Level Description/Impact Storage
Alarms Transceiver has detected one or
more alarm conditions
Flash
Memory
Informational Normal operating activities Flash
Memory
Temporary
Informational
Transient conditions or events RAM
Minor Does not affect unit operation RAM
Major Degraded unit performance but
still capable of operation
RAM
Critical Prevents the unit from operating RAM
Table 4-5. Alarm Conditions (Alphabetical Order)
Alarm Condition Reported Event Log Entry SNMP Trap
EVENT_BRIDGE Network Interface /Error networkInterface(17)
EVENT_FREQ_CAL Frequency Not
Calibrated
frequencyCal(7)
EVENT_INIT_ERR Initialization Error initializationError(18)
EVENT_IPADDR
*
IP Address Invalid ipAddressNotSet(4)
EVENT_IPMASK
*
IP Mask Invalid ipNetmaskNotSet(5)
EVENT_LAN_PORT lanPortStatus(78)
EVENT_MAC MAC communication
Failed
macCommunication(1)
EVENT_MACADDR MAC Address Invalid noMacAddress(6)
EVENT_NETNAME
*
Netname Invalid invalidNetname(12)
EVENT_POWER_CAL Power Calibrated/Not
Calibrated
powerCal(8)
EVENT_REMOTE Remote Added/
Removed (AP Only)
eventRemote(66)
EVENT_RSSI
*
RSSI Exceeds
threshold
rssi(11)