User's Manual Part 3

05-4446A01, Rev. D Mercury Reference Manual 153
* User can correct condition, clearing the alarm.
4.1.5 Correcting Alarm Conditions
(See
Event Log Menu on Page 112)
Table 4-6 provides likely causes of events that inhibit the unit from
operating, and possible corrective actions. The Event Description
column appears on the
Event Log screen.
4.1.6 Logged Events
The following events allow the transceiver to continue operation and do
not make the PWR LED blink. Each is reported through an SNMP trap.
EVENT_RSSI_CAL RSSI Not Calibrated rssiCal(9)
EVENT_SYSTEM_ERROR* System Error Cleared;
Please Reboot
systemError(16)
EVENT_TFTP_CONN TFTP connectivity
achieved
tftpConnection(73)
EVENT_TFTP_ERR Attempted TFTP
connection failed
tftpConnFailed(79)
Table 4-5. Alarm Conditions (Alphabetical Order) (Continued)
Alarm Condition Reported Event Log Entry SNMP Trap
Table 4-6. Correcting Alarm Conditions—Alphabetical Order
Event Log Entry Generating Condition Clearing Condition
or Action
Bridge Down The Bridge fails to be
initialized.
Contact factory Technical
Services for assistance.
General System
Error
Internal checks suggest unit
is not functioning properly.
Reboot the transceiver.
Initialization Error Unit fails to complete boot
cycle.
Contact factory Technical
Services for assistance.
Invalid IP Address The IP address is either
0.0.0.0 or 127.0.0.1.
Program IP address to
something other than 0.0.0.0
or 127.0.0.1.
Network Interface
Error
Unit does not recognize the
LAN interface.
Contact factory Technical
Services for assistance.
RSSI Exceeds
Threshold
The running-average RSSI
level is weaker (more
negative) than the
user-defined value.
Check the aiming of the
directional antenna at the
Remote; raise the threshold
level to a stronger
(less-negative) value.