- 6.1 Software Commands
- Entering Commands
- AK
- ALARM
- AMASK [0000 0000–FFFF FFFF]
- ASENSE [HI, LO]
- AUDIO [ON, OFF]
- BAUD [xxxxx abc]
- BIN [DATA, CLEAR]
- BOOT
- BUFF [ON, OFF]
- CKEY [ON–OFF]
- CTS [0–255]
- CTSHOLD [0–60000]
- DATAKEY [ON, OFF]
- DEV
- DEVICE [DCE, CTS KEY]
- DKEY
- DLINK [ON/OFF/xxxx]
- DTYPE [NODE/ROOT]
- DUMP
- EMP [ON/OFF]
- ETHADDR
- FORCEALARM [ON or OFF]
- FORCEDCD [ON or OFF]
- HELP
- INIT
- INIT [SDx]
- INIT [P-20]
- IPCONFIG
- KEY
- MENU
- MODEL1
- MODEL2
- MODEM [xxxx]
- OWM [XXX...]
- OWN [XXX...]
- PORT [RS232, RS485]
- PTT [0–255]
- PTTSIG [OFF, LOW, HI]
- PWR [20–37]
- RESTORECONFIG
- RESTOREDEFAULTS
- RMODE [X710, TRANSPARENT, PACKET, CMAC, HELP]
- RSSI
- RTSKEY [ON, OFF]
- RTU [ON/OFF/0-80]
- RX [xxx.xxxx]
- RXATTN [ON or OFF]
- RXLEVEL [–20 to 0]
- RXTOL [NORMAL or CUSTOM]
- RXTOT [NONE, 1-1440]
- SAVECONFIG
- SCD [0-255]
- SER
- SHOW [DC, PWR]
- SNR
- SPECTRUM [xxx.xx]
- SQUELCH [AUTO, BYPASSED]
- SREV
- STAT
- SWC [ON, OFF]
- TFTP
- TEMP
- TOT [1-255, ON, OFF]
- TX [xxx.xxxx]
- TXLEVEL [–20 to 0, AUTO]
- UNIT [10000...65000]
- UPTIME
- VERSION
- 7.0 TROUBLESHOOTING
- 8.0 TECHNICAL REFERENCE
- 8.1 Technical Specifications
- 8.2 Performing Network-Wide Remote Diagnostics
- 8.3 User-Programmable I/O Functions - Pending
- 8.4 Analog Operation of the Transceiver
- Physical Interface
- Operational Characteristics
- Web Method
- TFTP Method
- Serial Transfer Method
- Error Messages During File Transfers
- 9.0 GLOSSARY OF TERMS
30 SD Series Reference Manual (x710 Mode) MDS 05-4670A01, Rev. E
INIT
Initialize EEPROM
Defaults
The
INIT
command is used to re-initialize the radio’s operating parame-
ters to the factory defaults. This can be helpful when trying to resolve
configuration problems that might have resulted from the entry of one
or more improper command settings. If you are unsure of which com-
mand setting caused the problem, this command allows you to get back
to a known working state. The following changes to the radio are made
when
INIT
is entered:
•
CTS
is set to 0
•
DATAKEY
is set to
ON
•
DEVICE
is set to
DCE
•
PTT
is set to 0
•
SCD
is set to 0
•
TOT
is set to 30 seconds and set to
ON
•
PWR
is set to +37 dBm (5 watts)
All other commands remain as previously set.
INIT [SDx]
(Where “x” denotes SD radio model)
Initialization (for
standalone radio)
This command sets the transceiver for “normal” operation outside the
P-20 chassis by setting the following parameters to the values shown
below:
ASENSE ACTIVE HI
AMASK FFFF FFFF
(assert alarm output on all alarms)
RXTOT NONE
(receive time-out timer disabled)
Use this command to restore these three parameters to the standard
transceiver defaults if it was previously used in a P-20 package.
INIT [P-20]
Initialization for P-20
Implementation
This command sets the transceiver for service inside a P-20 redundant
chassis by setting the following parameters to the values shown below:
ASENSE ACTIVE LO
AMASK FFFF 0000
(trigger on major alarms)
RXTOT 20
(20 minute receive time-out timer)