User Manual
Table Of Contents
- Copyright and Trademark
- RF Safety Notice (English and French)
- FCC Part 15 Notice
- Industry Canada Notice
- 1.0 INTRODUCTION
- 2.0 PRODUCT DESCRIPTION
- 3.0 APPLICATIONS
- 4.0 INSTALLATION PLANNING
- 5.0 STEP-BY-STEP INSTALLATION
- 6.0 TRANSCEIVER MANAGEMENT
- 6.1 Software Commands
- Entering Commands
- AK
- ALARM
- AMASK [0000 0000–FFFF FFFF]
- ASENSE [HI, LO]
- AUDIO [ON, OFF]
- BAUD [xxxxx abc]
- BIN [DATA, CLEAR]
- BOOT
- BUFF [ON, OFF]
- CKEY [ON–OFF]
- CTS [0–255]
- CTSHOLD [0–60000]
- DATAKEY [ON, OFF]
- DEV
- DEVICE [DCE, CTS KEY]
- DKEY
- DLINK [ON/OFF/xxxx]
- DTYPE [NODE/ROOT]
- DUMP
- EMP [ON/OFF]
- ETHADDR
- FORCEALARM [ON or OFF]
- FORCEDCD [ON or OFF]
- HELP
- INIT
- INIT [SDx]
- INIT [P-20]
- IPCONFIG
- KEY
- MENU
- MODEL1
- MODEL2
- MODEM [xxxx]
- OWM [XXX...]
- OWN [XXX...]
- PORT [RS232, RS485]
- PTT [0–255]
- PTTSIG [OFF, LOW, HI]
- PWR [20–37]
- RESTORECONFIG
- RESTOREDEFAULTS
- RMODE [X710, TRANSPARENT, PACKET, CMAC, HELP]
- RSSI
- RTSKEY [ON, OFF]
- RTU [ON/OFF/0-80]
- RX [xxx.xxxx]
- RXATTN [ON or OFF]
- RXLEVEL [–20 to 0]
- RXTOL [NORMAL or CUSTOM]
- RXTOT [NONE, 1-1440]
- SAVECONFIG
- SCD [0-255]
- SER
- SHOW [DC, PWR]
- SNR
- SPECTRUM [xxx.xx]
- SQUELCH [AUTO, BYPASSED]
- SREV
- STAT
- SWC [ON, OFF]
- TFTP
- TEMP
- TOT [1-255, ON, OFF]
- TX [xxx.xxxx]
- TXLEVEL [–20 to 0, AUTO]
- UNIT [10000...65000]
- UPTIME
- VERSION
- 7.0 TROUBLESHOOTING
- 8.0 TECHNICAL REFERENCE
- 8.1 Technical Specifications
- 8.2 Performing Network-Wide Remote Diagnostics
- 8.3 User-Programmable I/O Functions - Pending
- 8.4 Analog Operation of the Transceiver
- Physical Interface
- Operational Characteristics
- Web Method
- TFTP Method
- Serial Transfer Method
- Error Messages During File Transfers
- 9.0 GLOSSARY OF TERMS
MDS 05-4670A01, Rev. E SD Series Reference Manual (x710 Mode) 53
Invisible place holder
Figure 23. PC Connection to Transceiver (Serial)
Follow the steps below for serial transfer upgrade.
NOTE: Serial reprogramming takes several minutes at 115200 bps
baud rate (the recommended speed), but reprogramming is
possible at lower baud rates.
1. Launch a terminal session to the radio with the following
communications parameters: Baud 115200, 8 data bits, no parity,
one stop bit (8N1), XON/XOFF flow control, and VT100 emulation.
2. At the
>
prompt, enter
program
. At the
ARE YOU SURE?
prompt, enter
yes
.
3. At the
LOADER>
prompt, enter
erase
. The response
ERASED OK
is
returned.
4. At the
LOADER>
prompt, enter
program
. Do not type any more char-
acters at the prompt.
5. From the terminal program, quickly select
Transfer->Send Text File
and choose the correct file/file folder on the PC where the
.s28
firm-
ware file is located.
This process initiates the file transfer and causes the radio to repro-
gram the inactive image. When using HyperTerminal to perform
reprogramming, no status indication is available.
6. Programming is complete when
PROGRAMMED OK
appears at the
prompt. The active image has now been changed to the new
package. If this message is not seen, reprogramming did not com-
plete successfully and must be attempted again.
7. Reboot the unit by typing the
exit
command at the
LOADER>
prompt.
This completes the serial upgrade procedure. To verify that the radio
is running the newly loaded firmware image, enter the
srev
com-
mand after rebooting.
PC Running Terminal Session
Transceiver
DB-9M to COM1 Port