Users Manual

MDS 05-6399A01, Rev. G MDS™ Master Station 115
Table 6-19. 100MHz LN Master Station Technical Specifications
Transmit (TX) Parameter
Specification
Frequency Range 150-174 MHz
Frequency Stability <0.5 ppm, -30C to +60C
TX Power Out
+38.8dBm (-0.2/+0.35dB),, Peak at radio card for-30 to +60C
1
+36.2dBm (+/-0.5dB), Peak, in redundant configuration with
integrated duplexer
Agency Approvals
FCC Part 90
Industry Canada RSS-119
Load VSWR 10:1 Max, All angles, No damage
Power Consumption <45W for all DC and AC versions, 100% TX Duty Cycle
Receive (RX) Parameter
Specification
Frequency Range 150-174 MHz
RX Intermodulation >60 dB
RX Adjacent Channel >60 dB
RX Spurious and Image >60 dB
RSSI Accuracy +/-3 dB for RSSI -110 to -30 dBm
RX High RF Input Level -20 dBm, no damage
Power Consumption <30W for all DC and AC versions, transmitter disabled
Noise Figure <4 dB
Operating Range -30°C to +60°C
1. Peak and average power are based on modem type:
a. 64QAM, 16QAM: Average power is 7dB less than peak
b. 4QAM: Average power is 5dB less than peak
6.6 Alarm and Alarm/Relay Modules
Figure 6-9 Alarm/Relay Module
There are 2 versions of the Alarm Module depending on whether the system is redundant or non-
redundant. The module pictured above is for redundant systems.