Users Manual
48 MDS™ Master Station MDS 05-6399A01, Rev. G
Table
5
-
2
. Modem Selection vs. Speed, Bandwidth & Sensitivity
Modem Type Se-
lection
Over-the-air
Speed (bps)
B/W (kHz)
Approximate
Sensitivity
(dBm)
ETSI Compli-
ance
9600
1
9600 12.5 -112
9600N 9600 6.25 -98
19200N 19200 12.5 -100
19200 19200 25 -105
38400N 38400 25 -99
65000
3
65000 50 See note 3
4800
1
4800 12.5 -112 X
9600M
1
9600 12.5 -106 X
19200E 19200 12.5 -96 X
19200M 19200 25 -106 X
4
38400E 38400 25 -97 X
4
1. For MDS x710-compatible operation.
2. 3200 bps not applicable to SD4.
3. Only available with SDM9D Radio Modules.
4. Not ETSI compliant on SDM4 Radio Modules.
Dlink
Dlink is a GE MDS-proprietary protocol used for diagnostics communications.
• Unit – This parameter identifies the radio in the wireless network with a specific ID
during diagnostic sessions. For compatibility with legacy devices, the value must be
10000 or greater (2710 in hexadecimal).
• Type – This setting identifies the radio as a Node, Root, Repeater, Peer, or Gate. Each of
these are operating modes of the transceiver with respect to diagnostic/management
activities.
• Mode – Configure if Dlink will operate on a serial port, or via a TCP socket.
• Serial Mode Settings: