User's Manual

38 MDS Master Station MDS 05-6399A01, Rev. D
Navigate to: Home / Services / Serial
Click on the name of the port (COM1, COM2, USB) to get:
• Line Mode - Selection of the operation line mode of the serial port. Choices are:
• RS232 (DEFAULT)
• RS485 - 2 Wire
• RS485 - 4 Wire
• Baud Rate - The serial port baud rate in bps. Choices are 1200, 2400, 4800, 9600, 19200, 38400,
57600, 115200 (DEFAULT)
• Byte Format - The data byte format in bits, parity and stop bits: Choices are:
• 7N1 - 7 char bits, no parity, 1 stop bit
• 7E1 - 7 char bits, even parity, 1 stop bit
• 7O1 - 7 char bits, odd parity, 1 stop bit
• 7N2 - 7 char bits, no parity, 2 stop bits
• 7E2 - 7 char bits, even parity, 2 stop bits
• 7O2 - 7 char bits, odd parity, 2 stop bits
• 8N1 - 8 char bits, no parity, 1 stop bit (DEFAULT)
• 8E1 - 8 char bits, even parity, 1 stop bit
• 8O1 - 8 char bits, odd parity, 1 stop bit
• 8N2 - 8 char bits, no parity, 2 stop bits
• 8E2 - 8 char bits, even parity, 2 stop bits
• 8O2 - 8 char bits, odd parity, 2 stop bits
• Hw Flow Control - Hardware flow control enable/disable (DEFAULT) using RTS/CTS lines