User's Manual

MDS 05-4121A01, Rev. 02 TRM SB Integration Guide 17
Invisible place holder
Figure 8. Data Interface Connector
(As viewed from above)
Table 4. DATA INTERFACE Connector Pinouts
Pin
Number
Input/
Output Pin Description
1 IN/OUT
Ground
2 OUT
RF synthesizer lock detect signal
High = locked (Radio ready for service)
Low = Out-of-lock (Radio disabled)
Raw / “unfiltered”
3IN
TX Data—Transmit Data
(payload) in normal operation
4 OUT
CD—Carrier Detect
Low whenever RSSI exceeds the programmed CDR
threshold.
Detects RF activity on the radio channel regarless of the
signals modulation type or data protocol.
5 IN/OUT
Ground
(Power and signal)
6 OUT
RX Clock—
Always applicable when receiving
Goes from low to high at the center of each RX Data bit
(receive mode). Data will be valid on falling edge.
Provided when transmitting if “
CLK RX
” is programmed
Goes from low to high to request each new TXD bit. Data
must be valid on falling edge.
Continuously high when transceiver is in Configuration
Mode (J100, Pin 11 = Low)
7 IN/OUT
Ground
(Power and signal)
8 OUT
TX Clock—Transmit Data Clock
Only applicable when “CLK TX” is programmed and TX
ON is asserted
Clock goes from low to high to request each new TXD bit.
Data must be valid on falling edge.
Continuously high when in Configuration Mode (J100,
Pin 11 = Low), or when “CLK RX” is selected