User's Manual
MDS 05-4121A01, Rev. 02 TRM SB Integration Guide 21
3.1 Error Messages
Listed below are some possible error messages that may be encountered
when using the terminal interface:
UNKNOWN COMMAND—The command was not recognized. Refer to the
command description for command usage information.
INCORRECT ENTRY—The command format or its associated values were
not valid. Refer to the command description for command usage
information.
COMMAND FAILED—The command was unable to successfully complete.
This may indicate an internal software problem.
NOT PROGRAMMED—Software was unable to program the internal radio
memory or the requested item was not programmed. This is a serious
internal radio error. Contact MDS for assistance.
TEXT TOO LONG—Response to OWN command when too many characters
have been entered. Refer to the command description for command
usage information.
NOT AVAILABLE—The entered command or parameter was valid, but it
referred to a currently unavailable choice. Refer to the command
description for command usage information.
OWN [xxx]
Owner’s Message
Displays an optional owner message
• Enter OWN to display current entry.
• Enter OWN followed by up to 30 characters to program.
KEY
Transmitter Carrier Key
• Test command for technicians to key the radio with a
unmodulated carrier.
• Use DKEY command to cease transmission
NOTES:
• Use only for test purposes.
• No time-out timer on this function.
DKEY
Unkey Transmitter Test Carrier
Table 5. Command Summary (Continued)
Command Function