Operating Instructions

RUNNING THE SOFTWARE
1. Connect ST600 to a suitable supply and to the PC using the programming
adaptor.
2. Insert the STSRn00.exe disk into drive A and type:
A:STSRn00 <return>
3. The user is then prompted to enter the serial port number of his PC which is
used to communicate with the ST600 receiver. Enter 1 or 2.
4. Next there is a prompt to select STn00 or SRn00. Enter 1 for the ST600
5. Next is the prompt to select freq. range: 1 : ST100 (125 - 180MHz)
2 : ST/SR500 (400 - 650MHz)
3 : ST/SR800 (800 - 880MHz)
After the software has successfully loaded the main menu screen is displayed as shown
in Figure 3. The screen shows the default settings which are entered at factory set-up.
These default settings will be displayed whenever the STSRn00 software is run.
Please note that mouse operation is not supported with this program.
FREQUENCY STORAGE
The internal PIC processor allows for both random allocated frequencies and
sequential channels. The program displays the 16 (as channel 0/ to 15) random
channels on the main screen. If a sequential table is used then these are stored in
channels 16 to 127. These cannot be displayed or printed out.
To simplify the situation, the first 16 channels of the sequential table can be copied to
the random channel by pressing the F2 button.
The first 8 channels (0 to 7) can be selected using the serial interface or the parallel
interface, as described later.