GE Endure Multi Series Brochure

Series
Outdoor Units
ASH220NCDWA ASH324NCDWA ASH436NCDWA
Cooling Non-Ducted
Rated Capacity Btu/hr 18,100 22,000 34,000
Capacity Range Btu/hr 7000-20000 6000-23600 6000-38000
Rated Power Input W 1448 1760 2,740
SEER 17 18.5 20
EER 12.5 12.5 12.50
Cooling Ducted
Rated Capacity Btu/hr 18,100 21,000 34,200
Capacity Range Btu/hr 6000-19000 6000-22300 6000-37000
Rated Power Input W 1724 2000 2,740
SEER 15 15 16.00
EER 10.5 10.5 10.00
Heating Non-Ducted
Rated Heating Capacity 47°F Btu/hr 20,000 24,000 36,000
Heating Capacity Range Btu/hr 8000-23000 8000-30600 8000-39000
Rated Power Input W 1504 1572 2,710
HSPF 10.5 10.5 10.50
COP @ 5°F 2.0 2.0 2.0
Max. Heating Capacity 5°F Btu/hr 23000 24000 36,000
Max. Heating Capacity -15°F Btu/hr 17000 18000 25,000
Heating Ducted
Rated Heating Capacity 47°F Btu/hr 20,000 22,000 35,000
Heating Capacity Range Btu/hr 8000-21000 8000-28600 8000-39000
Rated Power Input W 2255 2230 2710
COP 2.94 3 2.64
HSPF 9.6 9.3 10
COP @ 5°F 1.9 1.9 1.9
Max. Heating Capacity 5°F Btu/hr 19000 20000 35,000
Max. Heating Capacity -15°F Btu/hr 15000 16000 25,200
Power Supply
Voltage, Cycle, Phase V/Hz/- 208-230/60/1 208-230/60/1 208-230/60/1
Wire Size between ID and OD 14/4 AWG Stranded 14/4 AWG Stranded 14/4 AWG Stranded
Compressor Type DC Inverter Driven Rotary DC Inverter Driven Rotary DC Inverter Driven Rotary
Maximum Fuse Size A 25 25 40
Minimum Circuit Amp A 15 16 30
Outdoor Unit
Outdoor Fan Speed RPM 300~900 300~900 300~900
Outdoor Noise Level dB 56 56 55
Dimension: Height in (mm) 33.1(840) 33.1(840) 38.0 (965)
Dimension: Width in (mm) 37.3(948) 37.3(948) 37.4(950)
Dimension: Depth in (mm) 13.4(340) 13.4(340) 14.6(370)
Weight (Ship/Net)- lbs (kg) 202.3/185.6 (91.7/84.2) 205.9/189.5 (93.4/85.9) 241/221 (109.7/100.6)
Connectable Indoor unit quantity 2 2 or 3 2 3 or 4
Refrigerate Line
Connections Flare Flare Flare
Liquid O.D. in 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4
Suction O.D. in 3/8 3/8 3/8 3/8 1/2 3/8 3/8 3/8 1/2
Factory Charge Oz 99 99 113
Maximum Line Length Ft / m 164/50 196/60 230/70
Maximum Height Ft / m 50/15 50/15 50/15
Maximum Line Length for each indi-
vidual indoor unit Ft / m
82/25 82/25 82/25
-22 1151450-4
-1 5
Cooling
Heating
75
Operating Range (
O
F):
Endure features,
benefits, and
performance, available
now for multi-zone
applications.
Matching one outdoor unit with a variety
of multiple indoor units provides contractors
unprecedented application flexibility.
Series Outdoor
Capacity
Standard
Controller
Optional
Controller
7K 9K 12K 18K 24K
Endure
Multi
ASH220N
(2 Zone)
ASYW07U ASYW09U ASYW12U ASYW18U
ACT17CWA
ASH324N
(2 Zone)
AD07SL AD09SL AD12SL AD18SL
N/A
ACT17CWA
USYM09U
USYM12U USYM18U USYM24U
N/A
ACT17CWA
ASH436N
(4 Zone)
AB09SC AB12SC AB18SC
WJ01X24721
(YR-HG)
ACT17CWA
USYF09U USYF12U USYF18U
WJ01X24721
(YR-HG)
MULTI-ZONE SYSTEMS |
1 2