16.3.5 Personnel Tag (PT) Diagnostic Table
Symptom Possible Cause Corrective Action
PERSONNEL TAG (PT)
Unit
Battery Flat Charge or replace battery pack
Loss of Detection Zone
settings
Unit should still work with
factory default Detection Zone
settings (30 m range)
Contact Service Agent
HV not in gear Check HV gear status
No PT Alarm when within
HV (in gear) or TS
Detection Zone
Faulty Unit Replace with Spare Unit
Contact Service Agent for repair
No PT Detections by HV
(in gear) or TS when within
the PT Detection Zone
Faulty HV or TS tagged
object
HV (refer to Troubleshooting
section 16.3.1)
TS (refer to Troubleshooting
section 16.3.6)
Pulsed alarm (high rate)
when inside HV (in gear)
Detection Zone
“All of above” “All of above”
Pulsed alarm (low rate)
when inside TS Detection
Zone
Normal operation Normal operation
Continuous alarm (pulsed)
outside of HV or TS
Detection Zone
Normal operation Normal operation
Battery Low Charge or replace battery pack