21.9 Mobile Plant & Equipment System (PROD0225)
Power Source DC 12V +/- 10% (powered from suitable external 12VDC
power source via fused circuit e.g. permanent power
supply, battery power supply, solar power supply with
battery backing)
Power Consumption 57W maximum
Operating Temperature
0°C - 60°C
Storage Temperature
-20°C - 60°C
Operating Humidity 85 % RH max.
Storage Humidity 85 % RH max.
Protection Rating
Mobile Plant & Equipment Unit - IP 54 rated
enclosure
Dash Alarm Unit – IP 32 rated enclosure
Overall Dimension
Mobile Plant & Equipment Unit 200mm (W) x
250mm(H) x 165mm (D) (excluding magnetic
base)
Dash Alarm Unit 64 mm (W) x 25 mm (H) x 108
mm (D)
Weight
Mobile Plant & Equipment Unit 1.9 kg (excluding
magnetic base option)
Dash Alarm Unit – 82 g
Connectors Mobile Plant & Equipment Unit (PROD0250)
Power & I/O (12-way MILSPEC panel plug)
Antenna (UHF panel socket)
Dash Alarm Unit (PROD0211)
Power & Inputs (5-way subminiature DIN)
RS-232 Interface (DB-9 panel socket)
Input Signals Mobile Plant & Equipment Unit
Input Power (12 VDC, 55W max.)
Antenna
Dash Alarm Unit
Power (12VDC, 0.6W typical)
RS-232 data communications
Alarm signal
Output Signals Mobile Plant & Equipment Unit
Rotating Beacon Lamp (12V, 55W)
RS-232 data communications
Alarm Unit Power
Alarm signal
Dash Alarm Unit
Power indicator (POWER)
Alarm indicator (DETECT) & buzzer (volume set by
internal jumper links)
RS-232 data communications
Fuse Fuse to be installed in-line with power supply circuit
(7.5A, 20 mm x 5 mm slow blow)