Installation Preparation
POWER SUPPLY
IMPORTANT – (Please read carefully)
WARNING
FOR PERSONAL SAFETY, THIS
APPLIANCE MUST BE PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before
beginning installation.
Do not use an extension cord or adapter plug with
this appliance. Follow National Electrical Code or
prevailing local codes and ordinances.
Electrical supply
This vent hood must be supplied with 120V, 60Hz, and
connected to an individual, properly grounded branch
circuit, and protected by a 15- or 20-amp circuit
breaker or time-delay fuse.
■ Wiring must be 2-wire with ground.
■ If the electrical supply does not meet the above
requirements, call a licensed electrician before
proceeding.
■ Route house wiring as close to the installation
location as possible. Wiring can enter from the
ceiling or rear wall. Route additional length from the
ceiling or wall to reach the junction box.
■ Connect the wiring to the house wiring in
accordance with local codes.
Grounding instructions
The grounding conductor must be connected to
a ground metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.
WARNING
The improper connection of the
equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician or
service representative if you are in doubt whether the
appliance is properly grounded.
TOOLS AND MATERIALS REQUIRED
(Not Supplied)
Masking tape
Gloves
Utility Knife
Pliers
Wire cutter/stripper
Metal snips
Spirit level
Aluminized
duct tape
Safety glasses
120V 60Hz. 15- or 20-Amp,
2-wire with ground, properly grounded
branch circuit
Electrical Cable
Stepladder
Saber saw or Key Hole saw
Phillips screwdriver
Strain relief for
junction box
Strain Relief I
6″ round metal duct, length
to suit installation
Hammer
Electric drill with 1/8″ bits,
#2 Phillips and flat head
Flashlight
UL-listed wire nuts
Wire Nuts
Pencil and tape
measure