GE Monogram® Installation Instructions Professional Vent Hoods 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS 36" Models ZV671WSS, ZV681YSS ZV670WSS, ZV680YSS 30" Models ZV370YSS, ZV371YSS
Before you begin—Read these instructions completely and carefully. IMPORTANT: Save these instructions for local inspector’s use. IMPORTANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES. NOTE TO INSTALLER: Be sure to leave these instructions with the Consumer. NOTE TO CONSUMER: Keep these instructions with your Use and Care Book for future reference. WARNING This appliance must be properly grounded. See “Electrical Supply”, page 5.
Design Information Professional Vent Hoods Models Available Duct Cover Accessories These hoods can be installed into a soffit, or when there is no soffit, they can be installed directly onto a wall. 48" and 36" wide models are available with different appearances. Model numbers with “YSS” have straight sides. Model numbers ending with “WSS” have sides which taper inwards from the bottom to the top.
Design Information Professional Vent Hoods Product Dimensions & Clearances These vent hoods must be installed 30" Min. and 36" Max. above the cooking surface. Installation will be easier if the vent hood is installed before the range or cooktop installation. The rating plate is located behind filter cutouts. To verify your model number, remove filters.
Design Information Professional Vent Hoods Advance Planning Ductwork planning • Determine the exact location of the vent hood. • Plan the route for venting exhaust to the outdoors. • Use the shortest and straightest duct route possible. For satisfactory performance, duct run should not exceed 100 feet equivalent length for any duct configurations. • Refer to “Duct Fittings” chart to compute the maximum permissable length for duct runs to the outdoors. See page 6. • Use metal ductwork.
Installation Preparation Professional Vent Hoods Duct fittings Use this chart to compute maximum permissable lengths for duct runs to outdoors. Note: Do not exceed maximum permissable equivalent lengths! Maximum duct length: 100 foot for range hoods. Flexible ducting: If flexible metal ducting is used, all the equivalent feet values in the table should be doubled. The flexible metal duct should be straight and smooth and extended as much as possible. Do NOT use flexible plastic ducting.
Installation Professional Vent Hoods Tools & Materials Required (not supplied) 1 Step Remove the Packaging and Disassemble • Tape measure • Spirit level • Wire Cutter • Wire stripper • Electric drill and appropriate bits • Torx screwdriver Wall Mount Installation: • Six, 5/16" lag screws, 2" long with washers, all models (provided). • 120V 60Hz 15 or 20 Amp, 2 wire with ground. Properly grounded branch circuit. • Metal ductwork, 3-1/4" x 24" or 10" round for 48" wide model.
Installation Professional Vent Hoods 2 Step Check Installation Hardware 3 Step Construct Soffit Framing INSTALLATION UNDER A SOFFIT (SKIP THIS STEP IF SOFFIT IS NOT USED.) Locate the hardware accessory box packed with range hood and check contents. Filter(s) Heat Lamp(s) (on some models) Halogen Bulbs Grease Tray(s) We recommend that the vent hood and/or duct cover be on site before final framing and wall finishing to more accurately locate the ductwork and electrical service.
Installation Professional Vent Hoods 3A Step Construct Wall Mount Framing WALL MOUNT INSTALLATION (SKIP THESE STEPS IF SOFFIT IS USED.) NOTE: A decorative duct cover is available for wall mount installations. The duct cover conceals the duct run from the top of the hood to the ceiling. Choose the 6" or 12" cover based upon installation height of the vent hood. 7" Min. (30" and 36" Models) 10" Min.
Installation Professional Vent Hoods 4 • Drill 3/16" pilot holes through the shims and into the soffit studs. • Hold the hood against the soffit and secure with 6 lag screws with washers. • For additional support and to minimize vibration during operation, we recommend that the hood be secured to the back wall. • Drive lag screws through the rear panel of the hood and into the wall studs. Step Install Hood Below Soffit INSTALLATION UNDER A SOFFIT (SKIP THIS STEP IF SOFFIT IS NOT USED.
Installation Professional Vent Hoods 4A WALL MOUNT INSTALLATION • Drill 3/16" pilot holes, approximately 1-1/2" deep, in all mounting screw locations. • Hold the hood in position and drive lag screws in top left and right mounting holes. Step Install Hood Onto Wall Ceiling NOTE: 5/16" hanger bolts can be used in the two top locations. Place the hood onto the hanger bolts and secure with nuts and washers. WALL MOUNT INSTALLATION (SKIP THESE STEPS IF SOFFIT IS USED.
Installation Professional Vent Hoods 5 Step Connect Electrical Step 6 Connect Ductwork Verify that power is turned off at the source. CAUTION WARNING If house wiring is not 2-wire with a ground wire, a ground must be provided by the installer. When house wiring is aluminum, be sure to use U.L. approved antioxidant compound and aluminum-to-copper connectors. • Connect white lead to branch circuit white lead. • Connect black lead to branch circuit black lead.
Installation Professional Vent Hoods 8 Step “WSS” Duct Covers • Fasten the duct cover to the top of the hood with 2 screws. Install Duct Cover Secure with Screws “YSS” Duct Covers • Install one side piece to the top of the hood with 2 screws. Install opposite side piece. • Secure front panel to the side panels with 2 torx screws on each side (provided). 9 • Place the filter drip trays into the bottom of the opening.
Notes Professional Vent Hoods 14
Notes Professional Vent Hoods 15
Note: While performing installations described in this book, safety glasses or goggles should be worn. To obtain specific information concerning any Monogram product or service, call GE Answer Center® consumer information service at 800.626.2000—any time, day or night. For Monogram local ser vice in your area, call 1-800-444-1845. ® Monogram. General Electric Company Louisville, KY 40225 NOTE: Product improvement is a continuing endeavor at General Electric.