Installation instructions

8
Installation Preparation
INSTALLATION BELOW A COUNTERTOP
*NOTE: When installing the warming drawer below a cooktop, a solid barrier
must be installed at least 1” from the lowest point of the bottom of cooktop
burner box to the top of cutout. Use any solid material such as 1/4” thick
plywood. Allow at least 1/4” air gap between the barrier and the top of the
warming drawer. See label on top of the warming drawer for approved
cooktop models.
Installation below a cabinet drawer:
The warming drawer may be installed beneath a cabinet
drawer. In this installation, a solid barrier should be installed
above the warming drawer to block access. Use any solid
material such as 1/4” thick plywood. Allow at least 1/4”
air gap between the barrier and the top of the warming
drawer. Observe the 5” min. above the floor or 1” above the
toekick minimum installation height.
NOTE: If you are installing in frameless cabinets, it may
be necessary to install 1/2” wide cleats to accept drawer
mounting screws. See drawer to find exact locations of
mounting screws.
Side to Side Installation:
Install two warming drawers in separate cutouts.
Allow 2” min. between cutouts.
Install a Solid Barrier
Below a Cooktop
See Note
1-1/2” Cabinet Top
36”
Countertop
Height
1” Min.*
9-1/4”
9”
A
7”
25”
23-1/2” Min.
1/4”
Air
Gap
Solid Barrier
Electrical Outlet 42”
Max. From Right Side
Install a Solid Barrier
and a 1/4” Air Gap
Above Warming Drawer
Electrical
Outlet 16”
Max. From
Left Side
Install 2x4 or 2x2 Anti-Tip Block
Against Rear Cabinet Wall 9”
From Floor to Bottom of Block
Electrical Outlet
Flush With Side of
Cabinet 7” Max.
• When installed, the front face of the drawer will be
nearly flush with adjacent cabinetry doors.
Drawer overlaps will conceal cut edges on all sides of
the opening.
The rough opening for the drawer must be:
Depth: 23-1/2” min. from inside back to front of cabinet
frame.
Width: 25-1/2” for 27” wide models,
28-1/2” for 30” wide models.
– Height: 9-1/4”.
• 5” min. above floor or 1” above toekick. 23-1/4”
from floor to bottom of cutout is recommended for under
countertop installation.
Installation below a cooktop:
Warming drawers are approved for installation below only
certain specified cooktop models. See the label attached
to the top of the warming drawer for approved models. A
solid barrier and air gap between cooktop and warming
drawer is required. See Note above.
Dimensions
A
ZW9000 28-1/2”
ZJ7000 25-1/2”
Side to Side Installation
2”
Min.