User Manual

/RZVHWWLQJDGMXVWPHQWVPXVWEHPDGHZLWKRWKHUEXUQHUVLQ
operation on a medium setting. This procedure prevents the
ORZÀDPHIURPEHLQJVHWWRRORZUHVXOWLQJLQWKHÀDPHEHLQJ
extinguished when other burners are turned on.
A. Turn on all surface burners to medium setting.
% 7XUQWKHNQRERQWKHEXUQHUEHLQJDGMXVWHGWR³/2´
& 5HPRYHWKHNQREDQGLQVHUWDVPDOOÀDWEODGHVFUHZGULYHU
into the valve shaft and/or side adjustment screw(s) as
shown and turn clockwise to fully tighten down the bypass
screw(s). Repeat for all valves.
' ,IÀDPHDSSHDUVWRRORZRUXQVWDEOHVORZO\WXUQE\SDVVVFUHZ
FRXQWHUFORFNZLVHXQWLODVWDEOHÀDPHH[LVWVIRUHDFKEXUQHU
Remember, other burners must be turned on to medium.
SPECIALTY BURNERS
Dual Oval BurnerThis burner should be properly adjusted
with both bypass screws completely screwed in.
Multi-Ring Burner±7KHRXWHUULQJRIÀDPHVVKRXOGEH
DGMXVWHGZLWKWKHNQREDWWKH0('
by adjusting the set screw in the
FHQWHUYDOYHVKDIW7KHÀDPHVVKRXOG
be adjusted so that they barely curl
over the top edge of the burner cap.
7KHFHQWHUULQJRIÀDPHVVKRXOGEH
DGMXVWHGZLWKWKHNQREDWWKH/2
setting by adjusting the set screw to
the right of the valve shaft.
( $GGLWLRQDOO\IRUHDFKEXUQHUEHLQJDGMXVWHGTXLFNO\RSHQ
DQGFORVHWKHRYHQGRRUZKLOHREVHUYLQJÀDPH,IÀDPHLV
extinguished, continue adjusting bypass screw for a larger
ÀDPH5HSHDWGRRURSHQLQJVXQWLOÀDPHLVVWDEOH
F. Replace the knob.
ADDITIONAL INFORMATION
ADJUSTING LOW FLAME SETTING
ON COOKTOP BURNERS
PROPANE CONVERSION INSTRUCTIONS
31-10994-1 03-17 GEA
P2B940
NOTICE:
2QFHWKHFRQYHUVLRQLVFRPSOHWHDQGFRQ¿UPHG¿OORXW
the propane sticker and include your name, organization
and date conversion was made. Apply the sticker to
the range near the regulator to alert others in the future
that this appliance has been converted to propane. If
converting back to natural gas from propane, please
remove the sticker so others know the appliance is set to
use natural gas.
BURNER OUTPUT RATINGS: BTU/HR
NG (Natural) Gas 5” W.C.P.
BURNER
BTU
RATE
ORIFICE
SIZE (mm) COLOR MARKING
/) 20,000 1$
/) 1$ 0.043” (1.09) Blue/White 1
/) 1$ 0.043” (1.09) Blue/White 1
/) 1$ 0.043” (1.09) Blue/White 1
/)& 1$ 0.025” (0.63) 1RQH 1
RF 18,000 0.078” (1.98) 3XUSOH 1
/5 5,000 0.040” (1.01) :KLWH3XUSOH 1
RR 9,500 0.053” (1.36) *UHHQ 1
C 10,000
C1 1$ 0.055” (1.41) Yellow 1
C2 1$ 0.053” (1.36) *UHHQ 1
198
III
Denotes 1.98mm Orifice size opening
Denotes Natural Gas
N
Flames
Burner Cap
SPECIAL NOTE:
To convert the oven back to natural gas, reverse the
instructions given in making propane adjustments.
Adjustment screws for
dual oval burner only
Adjustment screws for
multi-ring burner only
Adjustment screw for
center ring
Adjustment screw for
outer ring
Adjustment
screw for
2 oval rings
Adjustment
screw for
center ring
Center adjustment screw
only for all other burners.