Quick Start Guide

Dimensions anD installation information
Dimension and installation information are shown in inches.
Listed by
Underwriters
Laboratories
PP9830sJ
GE Profile
Series 30" Downdraft Electric Cooktop
For answers to your Monogram
®
or GE
®
appliance
questions, visit our website at geappliances.com
or call GE Answer Center
®
service, 800.626.2000.
Specification Created 2/15
InstallIng the ductWork: Use
galvanized or aluminum duct in 6" round
or 3-1/4" x 10" size, or combination of both.
PVC duct or locally approved piping
should be used if installing under a
poured concrete slab. Local building code
must be followed in specifying type and
schedule of all duct used.
note: Ductwork must be vented to
outside. Do not vent into a wall, ceiling,
crawlspace, attic or any concealed space.
Always use an appropriate roof or wall cap
with damper.
Laundry-type wall caps should never
be used. For maximum efficiency use the
shortest and straightest duct run possible,
with as few fittings as possible.
For satisfactory performance the duct
run should not exceed 100 feet equivalent
length.
Refer to the table of equivalent lengths
(shown in installation instructions) for
various duct configurations.
rear Wall VentIngdoWnWard VentIng
Venting Options
Through Cabinet Toe Space
Inside Wall to Roof Direct to Outside
Between Floor Joist
9-1/8
10-1/8
18-3/4
6-1/8