User Manual

8
Installation Preparation
Preparation WITH an Accessory Storage Drawer
NOTE: MODEL ZSC2202 CANNOT BE INSTALLED WITH AN ACCESSORY STORAGE DRAWER. SEE
INSTALLATION PREPARATION WITHOUT AN ACCESSORY STORAGE DRAWER FOR THIS MODEL.
Installation over a GE/Monogram
Warming Drawer:
*
For existing cutouts, a maximum width of 28-1/2”
is acceptable. If the opening is slightly wider,
secure a furring strip on each side of the cutout
for securing the oven.
NOTE: Additional clearances between the
cutouts may be required. Check to be sure
the oven supports above the Warming Drawer
location do not obstruct the required interior depth
and height. See Warming Drawer installation
instructions for details.
30”
23-1/2”
25-1/4”
Min.*
21”
36-3/4”
Min.
Per warming
drawer
requirement
Construct
Solid Bottom
Min. 3/8”
Plywood
Supported
by 2x4 or 2x2
Runners all
Four Sides
PREPARE THE OPENING
The Advantium 240V can be installed in
combination with other GE/Monogram
appliances. Always follow each product’s
Installation Instructions to complete the
installation.
Single Advantium 240V Installation:
Order a 30” wide single oven cabinet or cut the
opening in a wall to the dimensions shown.
* For existing cutouts, a maximum width of
28-1/2” is acceptable. If the opening is slightly
wider, secure a furring strip on each side of the
cutout for securing the oven.
Always maintain 36-3/4” minimum height
from the floor to the cutout in any single or
combined installation.
Allow 3/4” to 2-1/8” case trim overlap on the
sides and 7/8” overlap on the bottom of the
opening for all models. The amount of overlap
on the sides depends on the actual cutout
width. Allow 1-1/4” case trim overlap on the top
for model PSB9120 and 3/4” overlap on the top
for models ZSC2200, ZSC2200, ZSC2201 and
ZSC2202.
Oven overlaps will conceal cut edges on all
sides of the opening.
30”
23-1/2”
25-1/4”
Min.*
21”
Construct
Base
Min. 3/8”
Plywood
Supported
by 2x4
or 2x2
Runners all
Four Sides
36-3/4”
Min.
PREPARE THE OPENING (CONT.)
Single Advantium 240V Installation (cont.)
When installed over a single oven or a warming
drawer, allow at least 2” between the two
openings. This separation will provide clearance
for bottom overlap of the Advantium 240V and the
other appliance overlaps.
Construct a solid oven floor of 3/8” min. thick
plywood supported by 2 x 4 or 2 x 2 runners on all
sides.
The support must be level and rigidly mounted,
flush with the bottom edge of the cutout.
2” Min.
(3” recommended)