Qucik Specs

Listed by
Underwriters
Laboratories
PVM9005EJ
GE Profile
Series
2.1 cu. ft. Over-the-Range Sensor Microwave Oven
Specification Revised 7/15
For answers to your Monogram,
®
GE Profile
or GE
®
appliance questions, visit our website
at geappliances.com or call GE Answer Center
®
service, 800.626.2000.
hooD exhaust Duct: Outside ventilation requires a hooD
exhaust Duct. Read the following carefully.
exhaust coNNectIoN: The hood exhaust has been designed to mate with
a standard 3-1/4" x 10" rectangular duct. If a round duct is required, a rectangular-
to-round transition adaptor must be used. Do not use less than a 6" diameter duct.
rear exhaust: If a rear or horizontal exhaust is to be used, care should be
taken to align exhaust with space between studs, or wall should be prepared
at the time it is constructed by leaving enough space between the wall studs to
accommodate exhaust.
maxImum Duct leNgth: For satisfactory air movement, the total duct
length of 3-1/4" x 10" rectangular or 6" diameter round duct should not exceed
120 equivalent feet.
elbows, traNsItIoNs, wall aND roof caps, etc., present additional
resistance to airflow and are equivalent to a section of straight duct which is
longer than their actual physical size. When calculating the total duct length,
add the equivalent length of all transitions and adaptors plus the lengths of all
straight duct sections. The chart below shows the approximate feet of equivalent
length of some typical ducts.
DImeNsIoNs aND INstallatIoN INformatIoN (IN INches)
Duct equIValeNt feet
A. Rectangular-To-round
Transition Adaptor
5 ft.
B. Wal l Cap 40 ft.
C. 90° Elbow 10 ft.
D. 45° Elbow 5 ft.
E. 90° Elbow 25 ft.
F. 45° Elbow 5 ft.
G. Roof Cap 24 ft.
optIoNal accessorIes (aVaIlable at aDDItIoNal cost)
fIlter KIt Jx81c–
recIrculatINg
charcoal fIlter KIt
To be used when the
microwave oven cannot
be vented to the outside.