Product Warranty

49-80777
13
INSTALLATION INSTRUCTIONS
Installation Preparation
VENTING OPTIONS
The downdraft vent is shipped with the
discharge outlet pointing straight down and
can be changed to the left or right side.
The blower outlet is sized for 3-1/4” x 10”
and can be transitioned to 6” round.
Side-to-Side Adjustments:
The entire blower mounting plate can be
adjusted 3-1/2” to the left or right. This
will help to align vent discharge to house
ductwork.
Discharge Direction
The blower assembly may be removed and turned 90°
for a left- or right-side discharge.
A left or right 90° direction adjustment should be
performed before dropping into the countertop
opening.
To change to a left or right discharge:
Remove the 4 screws holding the blower and the
mounting plate assembly to the downdraft vent.
Retain screws.
Remove blower assembly; turn it over to access
the 4 nuts holding the blower to the mounting plate.
Remove the nuts.
IMPORTANT: Do not lift motor by the power cable.
Turn the blower to the left or right discharge
direction and reinstall the 4 nuts.
Reinstall blower and mounting plate with original
screws.
The hood must vent down or to the left when
installed with a GE or Monogram gas cooktop to
avoid interference with the inlet of the gas cooktop.
Discharge Down
(As Supplied)
Loosen Screws
to Adjust
3-1/2" to
Left or Right
17-1/4"
16-3/8"
10-5/16"
4-1/4"
4-1/4"
4-1/4"
Discharge Down
(As Supplied)
Discharge Left
Discharge Right