Spec Sheet

Listed by
Underwriters
Laboratories
For answers to your Monogram, GE Café
, GE Profile
or GE Appliances
product questions, visit our website at geappliances.com or call
GE Answer Center
®
Service, 800.626.2000.
PTD90EBPTDG/RS
GE Profile
7.3 cu. ft. Capacity Smart Electric Dryer with Fabric Refresh
Specification Revised 1/22
27˝
11-3/4˝
Power Cord 5-1/2˝
3-1/4˝
1-3/4˝
5˝
3-7/8˝
8˝
38-1/2˝
43-7/8˝
30-1/2˝ to front panel
31-1/8˝ to door
28-7/8˝ to door
28-1/4˝ to front panel
23-1/4˝
Side View Rear View
PTD60(E/G)BSRWS, PTD60(E/G)BPRDG
5.7 cu. ft. Dryers
2
Back View
Power
Cord Hole
30-1/2
5.8, 6.0 and 7.0 cu. ft. Dryers
5
Back View
Power
Cord Hole
4-1/2
POWER CORD LOCATIONS
SIDE VIEW
BACK VIEW
REAR VIEW
ELECTRIC DRYER RATING:
240V 5600W 24A 60Hz
208V 4400W 22A 60Hz
EXHAUST OPTION: 4-way rear, right, left and bottom
CIRCUIT REQUIREMENTS: An individual, properly-grounded branch circuit,
protected by a 30-amp circuit breaker or a time-delay fuse, is required.
NOTE: Dryer wall outlet must be located within 36" of service cord entry and
acessible when dryer is mounted in position.
INSTALLATION INFORMATION: For complete information, see installation
instructions packed with your dryer.
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
Special Installation Requirements
ALCOVE OR CLOSET INSTALLATION:
- If your dryer is approved for installation in an alcove or closet, it will be stated
on a label on the dryer back.
- The dryer MUST be exhausted to the outside.
- Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side; 1" front, top and rear
- Closet doors must be louvered or otherwise ventilated and must contain a minimum
of 60 sq. in. of open area equally distributed. If this closet contains both a washer
and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
- No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
- The dryer MUST be exhausted to the outdoors.
- The installation must conform with the local codes, or in the absence of local codes, with
the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET INSTALLATION:
- Minimum clearances to combustible surfaces are: 0" both sides; 1" rear
DRYER EXHAUSTING INFORMATION : Use metal duct only, vertical and horizontal ducting.

Summary of content (3 pages)