Quick Specs
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
PHP9036DJ 
GE Profile
™
 Series 36" Built-In Touch Control Induction Cooktop 
For answers to your Monogram, GE Café
™
 Series, GE Profile
™
 Series or 
GE Appliances product questions, visit our website at geappliances.com 
or call GE Answer Center
®
 Service, 800.626.2000.
ADA
COMPLIANT
Listed by 
Underwriters 
Laboratories
Specification Revised 1/19
To insure accuracy, it is best to make a
template when cutting the opening in the counter
Electrical junction box 16" MIN.
below countertop
Cooktop
36"
20-3/8"
18-7/8"
33-3/4"
19-1/8" to
19-1/4"
33-7/8"
to 34"
PHP9036DJ
2-1/2" MIN.
Required
1-3/4" MIN.
to rear wall
4-5/8" at baffle near center 
ofunit (except when installed
above an approved wall 
oven) and 3-1/4" at rear 
of air intake
13" MAX. depth of unprotected
overhead cabinets (when no
hood or microwave is installed)
30" MIN. from countertop to
unprotected cabinet (when
no hood or microwave is
installed)
2" MIN. clearance
to side wall from cut-out
on both sides of cooktop
15" MIN. height from countertop
to nearest cabinet (including
light rails) on both sides of
cooktop
See label next
to nameplate for
MIN. clearance
to wall
IMPORTANT: Requires a 3" free area between 
the bottom of the cooktop to any combustible 
material, i.e., shelving. Free area not required 
when installing wall oven underneath cooktop. 
Refer to installation instructions. Requires 
a 15" minimum from cooktop to adjacent 
overhead cabinets. Units are furnished with a 
48" flexible armored cable. 
NOTE: 36" induction cooktops are approved 
for use over select GE 30" Single Wall Ovens 
and Warming Drawers. Refer to cooktop 
and wall oven/warming drawer installation 
instructions packed with product for current 
dimensional data. If installed with a GE 
Telescopic Downdraft System, consult both the 
cooktop and downdraft installation instructions 
packed with product before installing. Cooktop 
gas/electric supply may need to be re-routed 
to install downdraft. The countertop cutout 
requires 23-1/2" minimum flat countertop 
surface and 25" minimum total countertop 
depth. In addition, other clearances to front 
edge of the countertop must be considered.  
Before installing, consult installation 
instructions packed with product for  
current dimensional data. 
APPROXIMATE COOKING DIMENSIONS
KW R ATING
240V 11.1
208V 9.6
AMPERAGE
240V 50 Amps
†
208V 50 Amps
†
†
NOTE: Check local 
codes for required 
breaker size.
2-1/2" MIN
From front edge
of countertop to front
edge of cooktop cutout
31-1/4" MIN
From top surface
of countertop to
top surface of
wall oven support
platform
INSTALLATION ABOVE A WALL OVEN
INSTALLATION ABOVE A WALL OVEN