Quick Specs

PVM9005SJ/EJ/BL/FM
GE Profile
2.1 cu. ft. Over-the-Range Sensor Microwave Oven
Specification Revised 7/21
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
For answers to your Monogram, GE Café
, GE Profile
or GE Appliances
product questions, visit our website at geappliances.com or call
GE Answer Center
®
Service, 800.626.2000.
HOOD EXHAUST DUCT: Outside ventilation requires a HOOD
EXHAUST DUCT. Read the following carefully.
EXHAUST CONNECTION: The hood exhaust has been designed to mate
with a standard 3-1/4" x 10" rectangular duct. If a round duct is required, a
rectangular-to-round transition adaptor must be used. Do not use less than
a 6" diameter duct.
REAR EXHAUST: If a rear or horizontal exhaust is to be used, care should be
taken to align exhaust with space between studs, or wall should be prepared
at the time it is constructed by leaving enough space between the wall studs to
accommodate exhaust.
MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct
length of 3-1/4" x 10" rectangular or 6" diameter round duct should not exceed
140 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present
additional resistance to airflow and are equivalent to a section of straight
duct which is longer than their actual physical size. When calculating the total
duct length, add the equivalent length of all transitions and adaptors plus the
lengths of all straight duct sections. The chart below shows the approximate
feet of equivalent length of some typical ducts.
DUCT EQUIVALENT FEET
A. Rectangular-To-round
Transition Adaptor 5 ft.
B. Wa ll Cap 40 ft.
C. 90° Elbow 10 ft.
D. 45° Elbow 5 ft.
E. 9 Elbow 25 ft.
F. 45° Elbow 5 ft.
G. Roof Cap 24 ft.
WB06X10807 – Recirculating
Charcoal Filter Kit (included)
to be used when the microwave
oven cannot be vented to
the outside.